MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1128/spectrum.00225-23

Медицинская библиотека · Microbiology spectrum · 2023

A Multi-Laboratory Evaluation of Commercial Monkeypox Virus Molecular Tests.

Erster Oran, Levy Itzchak, Kabat Areej, Mannasse Batya, Levy Virginia, Assraf Hadar, Azar Roberto, Ben-Zvi Haim, Bradenstein Ritta, Bunder Olga, Fadeela Ayman, Keren-Naus Ayelet, Peretz Avi, Roif-Kaminsky Diana, Saleh Lolu, Schreiber Licita, Schwartz Orna, Shaked-Mishan Pninit, Sorek Nadav, Strauss Merav, Steinberg Rachel, Treygerman Orit, Zisman-Rozen Simona, Yishai Ruth, Tejman-Yarden Noa, Mendelson Ella, Sofer Danit

СтатьяПеревод в очереди

Аннотация

In this report, we describe the first national scale multi-laboratory evaluation of monkeypox virus (MPXV) DNA commercial PCR kits. The objective of this study was to evaluate 2 kits by different diagnostic laboratories across Israel. Ten standardized samples were tested simultaneously using the Novaplex (15 laboratories) and Bio-Speedy (seven laboratories) kits. An in-house assay based on previously published reactions was used as reference. Comparison of the results showed high intra-assay agreement between laboratories, with small variations for most samples. The in-house assay had an analytical detection limit of less than 10 copies per reaction. While the 2 commercial kits were able to detect specimens with low viral loads similarly to the in-house assay, significant differences were observed, in the Cq values and relative fluorescence (RF), between the assays. The RF signal of the in-house and Bio-Speedy assays ranged between 5,000 and 10,000 RFU, while the signal in the Novaplex assay was less than 600 RFU. Due to the kit measurement protocol, the Cq values of the Bio-Speedy kit were 5 to 7.5 cycles lower than those of the in-house assay. On the contrary, the Cq values of the Novaplex kit were significantly higher than those of the in-house assay, with differences of 3 to 5 cycles per sample. Our results suggest that while all assays were similar in their overall sensitivity, direct comparison of Cq values between them may be misleading. To our knowledge, this is the first methodical evaluation of commercial MPX test kits. We therefore anticipate that this study would help diagnostic laboratories in choosing a specific MPX detection assay. IMPORTANCE To the best of our knowledge, this study is the first methodical evaluation of commercial kits designed for Monkeypox virus detection. This was done by performing the same tests using the same sample set in multiple laboratories, simultaneously, on a national scale. It therefore provides important and unique information on the performance of such kits and provides a guideline for choosing the assay of choice for monkeypox virus diagnosis in a standard diagnostic laboratory. It also demonstrates potential complications when trying to compare the results of different assays, even when testing exactly the same samples, under identical conditions.

Для цитирования: Erster Oran, Levy Itzchak, Kabat Areej, Mannasse Batya, Levy Virginia, Assraf Hadar, Azar Roberto, Ben-Zvi Haim, Bradenstein Ritta, Bunder Olga, Fadeela Ayman, Keren-Naus Ayelet, Peretz Avi, Roif-Kaminsky Diana, Saleh Lolu, Schreiber Licita, Schwartz Orna, Shaked-Mishan Pninit, Sorek Nadav, Strauss Merav, Steinberg Rachel, Treygerman Orit, Zisman-Rozen Simona, Yishai Ruth, Tejman-Yarden Noa, Mendelson Ella, Sofer Danit. A Multi-Laboratory Evaluation of Commercial Monkeypox Virus Molecular Tests.. Microbiology spectrum. 2023. DOI: 10.1128/spectrum.00225-23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.