MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11748-026-02325-4

Медицинская библиотека · General thoracic and cardiovascular surgery · 2026

Renal protection by intermittent cold crystalloid perfusion during thoracoabdominal aortic aneurysm repair.

Hayama Masato, Kuwahara Go, Wada Hideichi, Teratani Hiromitsu, Furui Masato

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Renal dysfunction is a major postoperative complication of thoracoabdominal aortic aneurysm repair and is closely associated with increased mortality. We adopted a simple method involving intermittent cold crystalloid perfusion into the renal arteries using gravity infusion during thoracoabdominal aortic aneurysm repair and evaluated its effectiveness.

METHODS

Between April 2011 and January 2024, 63 patients underwent open thoracoabdominal aortic aneurysm repair at Fukuoka University Hospital. After excluding 11 cases, 52 cases were retrospectively analyzed. Intermittent renal perfusion was performed using 4 °C lactated Ringer solution containing mannitol and methylprednisolone. Patients were classified into chronic kidney disease (< 45 mL/min) and non-chronic kidney disease groups (≥ 45 mL/min) based on the preoperative estimated glomerular filtration rate, and renal function was assessed.

RESULTS

There were no significant differences in operative or ischemic parameters between the groups. Postoperative acute kidney injury (Kidney Disease: Improving Global Outcomes stage ≥ 2) occurred in 21% of all patients, with no significant difference between the groups. Serum creatinine levels increased transiently postoperatively in both groups but returned to baseline or improved at discharge. No patient required long-term dialysis. Urine output tended to be higher in the chronic kidney disease group than in the non-chronic kidney disease group, particularly during the early postoperative period.

CONCLUSIONS

Intermittent cold crystalloid perfusion is a simple and effective method for renal protection in thoracoabdominal aortic aneurysm repair with favorable clinical outcomes regardless of preoperative renal function. The absence of permanent dialysis cases suggests that this approach is safe and feasible, particularly in emergencies and resource-limited settings.

Для цитирования: Hayama Masato, Kuwahara Go, Wada Hideichi, Teratani Hiromitsu, Furui Masato. Renal protection by intermittent cold crystalloid perfusion during thoracoabdominal aortic aneurysm repair.. General thoracic and cardiovascular surgery. 2026. DOI: 10.1007/s11748-026-02325-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.