MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/vaccines14050461

Медицинская библиотека · Vaccines · 2026

In-Use Stability and Device Compatibility Define Clinically Actionable Handling Limits for a GMP-Produced Attenuated Listeria monocytogenes Vaccine Expressing GUCY2C.

Singh Jagmohan, Johar Taranjot, Scully Vannessa, Waldman Scott A, Bashir Babar, Snook Adam E

СтатьяПеревод пока не подготовлен

Аннотация

Background

Live-attenuated Listeria monocytogenes (Lm) vectors are a clinically validated cancer immunotherapy platform, but translation requires reproducible, clinically realistic workflows for dose preparation and infusion. For live bacterial products, in-use stability and device compatibility can drive dose variability through adsorption, settling, and device losses.

Methods

We developed and GMP-manufactured an attenuated Lm vaccine expressing human GUCY2C (Lm-GUCY2C) and performed translational characterization, including construct verification and immunogenicity readouts, and defined the administration-focused in-use stability and device compatibility. Post-thaw stability was assessed in primary cryovials and during preparation and delivery from 250 mL saline infusion bags using standard clinical devices (syringes/needles, filter-free IV tubing) and OnGuard2 closed-system components. Samples were collected over 24 h at room temperature, and viable Lm-GUCY2C were quantified by CFU recovery.

Results

Lm-GUCY2C remained stable in thawed cryovials for 24 h with no significant CFU loss. High-dose infusion bags (3 × 109 CFU/bag) maintained CFU recovery through 6 h, whereas low-dose bags (3 × 108 CFU/bag) exhibited significant losses beginning at 3 h, supporting a practical in-use window of up to 2 h for low-dose preparations. OnGuard2 intravenous (i.v.) connectors did not measurably affect CFU recovery, while OnGuard2 vial adapters reduced recovery.

Conclusions

This work provides an end-to-end, translationally focused characterization of a GMP-manufactured Lm cancer vaccine, including clinically actionable in-use handling constraints and device compatibility. These data define preparation and administration guardrails (notably, time-to-infusion limits for low-dose bag preparations) that can improve dose accuracy and reproducibility in clinical testing.

Для цитирования: Singh Jagmohan, Johar Taranjot, Scully Vannessa, Waldman Scott A, Bashir Babar, Snook Adam E. In-Use Stability and Device Compatibility Define Clinically Actionable Handling Limits for a GMP-Produced Attenuated Listeria monocytogenes Vaccine Expressing GUCY2C.. Vaccines. 2026. DOI: 10.3390/vaccines14050461.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.