m+Medelevator.RU
← Поиск публикаций
Biosensors & bioelectronics · 2026

Nanomolar electrochemiluminescence via smartphone: Image encoding matters.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gajjala Rajendra Kumar Reddy, Díaz Mikel, Lopez-Iturri Peio, Picallo Imanol, D'Arrigo Elisa, Rodríguez-Muiña Stephania, Eguizabal Cristina, Sojic Neso, Falcone Francisco, Del Campo Francisco Javier

Аннотация

Smartphone electrochemiluminescence detection is a practical route to decentralized diagnostics, but three error sources that the literature has largely overlooked limit sensitivity: unconstrained acquisition parameters, nonlinear gamma encoding in consumer image pipelines, and lossy JPEG compression. We show that addressing all three simultaneously yields nanomolar detection limits with a mid-range Android device. Long-exposure RAW images captured under fixed conditions are analyzed by full-histogram integration of the linearized red channel, applying the inverse sRGB transfer function to restore proportionality between pixel intensity and emitted radiance. On screen-printed glassy carbon electrodes with the tris(2,2'-bipyridine)ruthenium(II)/tripropylamine system, this workflow gives a detection limit of 16 nM and a quantification limit of 53 nM in solution, below values reported with any previous smartphone-based system. We also show that lossy JPEG export suppresses blank pixel variance by 16-25%, generating detection limits that appear competitive but carry no analytical meaning; lossless image formats are therefore a requirement for reliable low-concentration quantification. The complete pipeline runs in ECLiCare, an Android application that operates entirely on-device without cloud connectivity. Performance was validated against professional image-processing software on solution-phase data and on a bead-based sandwich immunoassay for epidermal growth factor receptor, where the linearized workflow gives a detection limit of 2.31 μg mL-1. This work provides a quantitative framework for smartphone electrochemiluminescence imaging that is ready for field and point-of-care deployment.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты