MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/strokeaha.126.055813

Медицинская библиотека · Stroke · 2026

Generating Synthetic MR Perfusion Maps From DWI and FLAIR in Acute Ischemic Stroke: Development and External Validation of a Deep Learning Model.

Matsulevits Anna, Koch Alexander, Mahé-Verdure Clara, Bendszus Martin, Hilbert Adam, Boullet Mary, Marnat Gaultier, Mutke Matthias A, Aydin Orhun Utku, Olindo Stéphane, Sibon Igor, Thiebaut de Schotten Michel, Frey Dietmar, Tourdias Thomas

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Magnetic resonance imaging (MRI) is critical for acute stroke triage, but it is time-consuming and often requires contrast injection for perfusion imaging. This study aimed to synthesize T-map perfusion maps from routinely available, noncontrast diffusion-weighted imaging and fluid-attenuated inversion recovery using deep generative models. We hypothesized that relevant perfusion information could be inferred from these modalities to streamline imaging and reduce reliance on dynamic susceptibility contrast perfusion.

METHODS

Acute magnetic resonance imaging data from 355 patients with anterior circulation stroke, including dynamic susceptibility contrast perfusion, were retrospectively collected from 2 European centers (Heidelberg: 2010-2018; Bordeaux: 2021-2022). Six versions of a denoising diffusion probabilistic model and a generative adversarial network architecture were trained to generate synthetic time-to-maximum (T-max) perfusion maps from diffusion-weighted imaging, fluid-attenuated inversion recovery, and infarct core mask as inputs. Performance was assessed by comparing synthetic and ground-truth T-max maps using image similarity metrics. Regions with T-max >6 s were compared using Dice coefficients, and mismatch volume distributions were analyzed. An ablation study quantified the contribution of each input.

RESULTS

The best performance was achieved by a denoising diffusion probabilistic model with a 2.5-dimensional architecture using diffusion-weighted imaging, fluid-attenuated inversion recovery, infarct core mask, and a perfusion-weighted loss function. It produced synthetic perfusion T-max maps with high similarity to ground truth under 110 s. The model showed strong spatial overlap for T-max> 6 s regions in internal validation (average Dice, 0.82; SD, 0.08) and external validation (average Dice, 0.59; SD, 0.13), respectively. Synthetic maps closely matched ground truth mismatch distributions, capturing key perfusion patterns. The infarct core mask played a critical role in model performance, alongside diffusion-weighted imaging and fluid-attenuated inversion recovery inputs.

CONCLUSIONS

We propose a noninvasive, scalable framework to generate synthetic T-max perfusion maps from noncontrast magnetic resonance imaging. This approach could expand access to perfusion data in acute stroke, shorten imaging protocols, and accelerate treatment decisions by eliminating the need for contrast-enhanced acquisition.

Для цитирования: Matsulevits Anna, Koch Alexander, Mahé-Verdure Clara, Bendszus Martin, Hilbert Adam, Boullet Mary, Marnat Gaultier, Mutke Matthias A, Aydin Orhun Utku, Olindo Stéphane, Sibon Igor, Thiebaut de Schotten Michel, Frey Dietmar, Tourdias Thomas. Generating Synthetic MR Perfusion Maps From DWI and FLAIR in Acute Ischemic Stroke: Development and External Validation of a Deep Learning Model.. Stroke. 2026. DOI: 10.1161/strokeaha.126.055813.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.