MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ekir.2026.106583

Медицинская библиотека · Kidney international reports · 2026

Randomized Controlled Study of Sirolimus-Coated Balloons for Dysfunctional Hemodialysis Fistulas.

Tan Chieh Suai, Tan Ru Yu, Ho Pei, Tieng Chek Choke Edward, Tan Chee Wooi, Ren Kwang Tng Alvin, Lim Gek Hsiang, Tay Hsien Ts'ung, Da Zhuang Kun, Ng Jun Jie, Vijaykumar Kalpana, Kang Lie Aw Darius, Chong Tze Tec, Tay Kiang Hiong, Pang Suh Chien, IMPRESSION investigators

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Restenosis following balloon angioplasty remains a major cause of arteriovenous fistula (AVF) dysfunction in patients receiving maintenance hemodialysis. We evaluated whether the use of sirolimus-coated angioplasty balloons (SCBs) improves access circuit primary patency (ACPP) in patients with dysfunctional, nonthrombosed AVFs.

METHODS

In this investigator-initiated, multicenter, single-blinded, randomized controlled trial (ClinicalTrials.gov identifier: NCT04409912), we enrolled 170 patients from 3 tertiary teaching hospitals in Singapore. Patients with dysfunctional AVFs, including those with single or multiple stenotic lesions within the access circuit, were included. Following successful plain balloon angioplasty (PBA) (< 30% residual stenosis on digital subtraction angiography), the patients were randomly assigned, using a centralized web-based system, to receive additional treatment with SCB (n = 83) or placebo balloons (n = 87). During the 12-month follow-up, the patients and their managing physicians were blinded to the study treatment and placebo. The proceduralists and coordinators could not be blinded because of visible differences between the balloons. The primary end point was ACPP during the first 6 months after the index procedure. Secondary end points included 12-month patency and safety outcomes.

RESULTS

In both intention-to-treat (ITT) and per-protocol (PP) analyses, 6-month ACPP was significantly higher in the SCB group than in the placebo group (P = 0.03). At 6 months, 70.1% (95% confidence interval [CI]: 58.7-78.8) of patients treated with SCB remained patent, compared with 56.7% (95% CI: 45.5-66.4) in the placebo group. At 12 months, the difference in patency was not statistically significant in the ITT analysis (37.1% vs. 27.7%; P = 0.07) but remained significant in the PP analysis (36.4% vs. 25.2%; P = 0.04). Adverse events were infrequent and no deaths occurred within 30 days in both groups.

CONCLUSION

Use of SCB following successful PBA improved 6-month ACPP in patients with dysfunctional AVFs, including those with multiple stenotic lesions. Short-term safety findings were reassuring.

Для цитирования: Tan Chieh Suai, Tan Ru Yu, Ho Pei, Tieng Chek Choke Edward, Tan Chee Wooi, Ren Kwang Tng Alvin, Lim Gek Hsiang, Tay Hsien Ts'ung, Da Zhuang Kun, Ng Jun Jie, Vijaykumar Kalpana, Kang Lie Aw Darius, Chong Tze Tec, Tay Kiang Hiong, Pang Suh Chien, IMPRESSION investigators. Randomized Controlled Study of Sirolimus-Coated Balloons for Dysfunctional Hemodialysis Fistulas.. Kidney international reports. 2026. DOI: 10.1016/j.ekir.2026.106583.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.