Enhanced label-free SERS detection of uremic toxins in clinical spent dialysate.

Lee Han, Liao Jiunn-Der, Guo Yi-Shan, Wang Chung-Yu, Liu Kuan-Hung, Lai Szu-Hsueh, Lin Bo-Shen

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

β2-microglobulin (β2-m) and leptin are key biomarkers for assessing the progression of chronic kidney disease and the efficacy of dialysis. Traditional biochemical assays are often time-consuming or require expensive consumables. Due to the low surface-enhanced Raman spectroscopy (SERS) activity of the characteristic functional groups of β2-m or leptin, the enhancement intensity of substrate-based label-free SERS may be weak. This work designs a method that combines modified Ag NPs (mAg NPs) with Au NPs/ZrO2 substrate (Au NPs/fZrO2 or Au NPs/pZrO2) to approach target species and constructs a feature recognition system for the detection of β2-m and leptin in clinical spent dialysate.

RESULTS

SERS spectral analysis of purified β2-m and leptin was performed using mAg NPs with Au NPs/ZrO2 to investigate their Raman characteristic peaks. First, reference and indicator peaks were identified to distinguish β2-m and leptin. Importantly, the major species Trp95 of β2-m was likely located near the mAg NPs, while the minor species Trp60 was located near the protein core, similar to the major species Leu51 and Phe41 in leptin.

SIGNIFICANCE: This constructed detection system utilizes synergistic plasmon coupling between Au NPs on a substrate and mAg NPs surrounding the target species to enhance the Raman signal and generate local hotspots, thereby improving signal reproducibility and detection sensitivity even in complex clinical media. Characteristic peak enhancement is most pronounced near the major species Trp95 of β2-m, but less noticeable with less exposure in the protein core or target species. It is significant to evaluate dialysis performance and contribute to dialysis monitoring.

Для цитирования: Lee Han, Liao Jiunn-Der, Guo Yi-Shan, Wang Chung-Yu, Liu Kuan-Hung, Lai Szu-Hsueh, Lin Bo-Shen. Enhanced label-free SERS detection of uremic toxins in clinical spent dialysate.. Analytica chimica acta. 2026. DOI: 10.1016/j.aca.2026.345601.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.