Restenosis patterns and clinical significance following VIABAHN endoprosthesis placement for refractory arteriovenous graft outflow stenosis.
Аннотация
OBJECTIVE
In this retrospective, single-center, observational study, we classified target lesion restenosis patterns following initial GORE® VIABAHN® endoprosthesis (stent graft) placement, calculated target lesion primary patency (TLPP) stratified by restenosis pattern, and examined their clinical significance.
METHODS
A total of 104 stent graft procedures performed between January 2020 and December 2024 were included in the analysis. Patency from stent graft placement to 1st target lesion revascularization (TLR), from 1st to 2nd TLR, and from 2nd to 3rd TLR was defined as 1st, 2nd, and 3rd TLPP, respectively. We divided target lesion restenosis into two groups: pattern E (edge), which extended up to 5 mm from the downstream edge of stent graft, and pattern D (downstream), which extended beyond 5 mm distal to the downstream edge of stent graft. TLPP was estimated using Kaplan-Meier analysis, and multivariable Cox proportional hazards regression was performed to identify predictors TLPP. The correlation between the elephant trunk (ET) technique (stent graft diameter < outflow vein diameter) and the restenosis pattern was evaluated using Fisher's exact test.
RESULTS
The 1st TLPP, 2nd TLPP, and 3rd TLPP were 81%, 41%, and 17% at 6 months, respectively. There was no significant difference in the TLPP between the groups with and without ET technique. The second TLPP in the Pattern D group was significantly worse than in the Pattern E group (p < 0.005). On multivariable analysis, restenosis pattern (HR = 3.23 (1.59-6.53), p = 0.001) and female sex (HR = 2.33 (1.17-4.68), p = 0.017) were significant predictors of 2nd TLPP. Fisher's exact test revealed a significant positive correlation between the ET technique and pattern E restenosis (p = 0.014, <0.001, and <0.001, for 1st, 2nd, and 3rd target lesion, respectively).
CONCLUSION
Time to loss of TLPP was progressively reduced with each successive balloon angioplasty. Pattern D was associated with poorer TLPP. Restenosis pattern E was significantly correlated with ET technique.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.