Медицинская библиотека · Renal failure · 2026

Impact of the drug-coated balloon-to-predilation balloon diameter ratio on restenosis risk in hemodialysis access: a study of nonlinear association.

Zhou Aiqiang, Lu Yong, Hu Liangzhu, Wang Chao, Zi Yafei, He Yedong, Huang Tao, Wen Luxiang, Liu Yangdong

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Drug-coated balloons (DCBs) improve the patency of hemodialysis access, yet restenosis rates remain substantial. This may be partly attributable to suboptimal balloon sizing. The relationship between the balloon diameter ratio (BDR; the ratio of DCB diameter to final predilation balloon diameter) and restenosis risk has not been clearly elucidated.

METHODS

This retrospective study analyzed 123 patients who underwent DCB angioplasty for dysfunctional arteriovenous fistulas (AVF) or arteriovenous grafts (AVG). The primary endpoint was clinically driven target lesion restenosis within six months. Multivariable Cox regression and restricted cubic spline (RCS) analyses were used to evaluate the association between BDR and restenosis.

RESULTS

The six-month restenosis rate was 25.2%. BDR was an independent predictor of restenosis (p = 0.048). Compared to a BDR of 1.0 (a perfect 1:1 match), a BDR < 1 was associated with a significantly higher risk (HR 3.07, 95% CI 1.01-9.34). RCS analysis demonstrated a significant U-shaped nonlinear relationship (P for nonlinearity = 0.041), with the risk nadir observed at a BDR of approximately 0.98. A BDR within the 0.9-1.1 range constituted a "safe window" associated with the lowest risk of restenosis.

CONCLUSIONS

BDR is a key, modifiable technical factor influencing patency after hemodialysis access intervention. Maintaining a BDR within the 0.9-1.1 range correlates with the lowest 6-month restenosis risk, yielding a clear and practical technical target for optimizing DCB angioplasty procedures.

Для цитирования: Zhou Aiqiang, Lu Yong, Hu Liangzhu, Wang Chao, Zi Yafei, He Yedong, Huang Tao, Wen Luxiang, Liu Yangdong. Impact of the drug-coated balloon-to-predilation balloon diameter ratio on restenosis risk in hemodialysis access: a study of nonlinear association.. Renal failure. 2026. DOI: 10.1080/0886022x.2026.2640723.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.