DOI 10.1016/j.xkme.2026.101244
Determining Physical Function Measures for Estimating VO2Peak in Patients Receiving Hemodialysis.
Аннотация
RATIONALE &
OBJECTIVE
Cardiopulmonary exercise testing is the gold standard for evaluating cardiovascular functional capacity, as assessed by oxygen uptake at peak exercise (VO2Peak). Traditional physical function tests have been proposed as predictive of VO2Peak, although their associations remain inconclusive in individuals with kidney failure. This study aimed to assess whether comprehensive physical function metrics are associated with VO2Peak in patients receiving hemodialysis.
STUDY
DESIGN
Cross-sectional analysis from the "Effects of Long Interdialytic Intervals on Cardiovascular Functional Capacity (ECON)" study.
SETTING &
PARTICIPANTS
Thirty patients with kidney failure receiving maintenance thrice-weekly hemodialysis.
PREDICTORS: Physical function tests.
OUTCOMES: VO2Peak (mL·min-1·kg-1) measured by cardiopulmonary exercise testing, with participants dichotomized into Low (n=14) and High (n=16) VO2Peak groups.
ANALYTICAL APPROACH: Group comparisons for demographics and physical function measures were performed. Multivariable linear regression was used to assess associations.
RESULTS
The Low and High groups were well matched by age, sex, and race (all P ≥ 0.05). However, body mass index (32.7 ± 6.7 kg/m2 vs 26.9 ± 6.5 kg/m2; P = 0.02) and fat mass composition (41.8 ± 7.3% vs 28.9 ± 12.0%; P = 0.002) were significantly higher in the Low group. The Short Form-36-Physical Function Scale total score, standing static balance test score, number of sit-to-stands in 30 seconds (30sec-STS), total Short Physical Performance Battery score, Patient-Reported Outcomes Measurement Information System physical function computerized adaptive testing, Patient-Reported Outcomes Measurement Information System physical mobility computerized adaptive testing, handgrip strength, and 6-minute walk test were all significantly associated with VO2Peak (all P < 0.05). However, after adjusting for age, sex, and fat mass composition, only 30sec-STS was significantly associated with VO2Peak (P = 0.04).
LIMITATIONS: The study's small sample size and cross-sectional design limit statistical power and causal inference.
CONCLUSIONS
Metrics of basic physical function demonstrate limited association with VO2Peak in patients on hemodialysis, except for the 30sec-STS test.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.