MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s1049023x26108930

Медицинская библиотека · Prehospital and disaster medicine · 2026

Capacity-Responsive COVID-19 Testing Performance in Emergency Departments: Turnaround Time Thresholds for Lateral Flow Assay and Polymerase Chain Reaction Strategies.

Chen Cheng-Han, Lee Yi-Tzu, Li Li-Hua, Hsu Teh-Fu, How Chorng-Kuang, Cheng Chao-Min

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

During the coronavirus disease 2019 (COVID-19) pandemic, emergency departments (EDs) faced unprecedented operational stress compounded by mandatory testing requirements that directly influenced patient flow and length-of-stay (LOS). Two testing modalities were central to pandemic ED operations: (1) rapid point-of-care lateral flow assays (LFAs), which return results in minutes but depend on frontline ED personnel and space, and (2) laboratory-based polymerase chain reaction (PCR), which requires sample transport and centralized processing but functions independently of ED capacity. Whether the relative performance of these modalities remains robust under varying ED operational pressures is unclear.

METHODS

This retrospective observational study analyzed 31,737 COVID-19 testing encounters (11,098 LFA; 20,639 PCR) during the 11-month dual-testing period (May 2022-March 2023) at a high-volume tertiary ED, when both modalities were concurrently deployed. Propensity score matching (PSM; 1:1 nearest-neighbor, caliper 0.5 SD) generated 8,492 well-balanced LFA-PCR pairs. Turnaround time (TAT) was evaluated as an operational stress indicator modifying the association between testing modality and ED LOS. Variability analyses assessed performance stability under differing capacity levels.

RESULTS

Overall, LFA was associated with longer LOS than PCR (median 8.3 versus 5.8 hours; P < 0.001). Under low-stress conditions (TAT ≤30 minutes), this difference was modest (median difference 1.5 hours; 95% CI, 0.80 to 2.07). As TAT increased, modality performance diverged substantially. At TAT >90 minutes, LOS difference increased to 3.6 hours (95% CI, 2.85 to 4.42). Threshold inflection occurred between 60-90 minutes. Lateral flow assays exhibited higher operational variability (CV ratio 2.09; 95% CI, 1.25 to 3.12), with the greatest instability during high-volume periods, while PCR performance remained comparatively stable across stress levels. Stratified analyses were exploratory; confidence intervals were not adjusted for multiplicity.

CONCLUSION

Turnaround time and its variability serve as actionable, real-time indicators of ED system capacity. Lateral flow assay performance degrades progressively under operational strain due to its reliance on frontline ED resources, whereas PCR-supported by external laboratory infrastructure-maintains more stable throughput. Capacity-contingent, adaptive testing strategies that shift toward PCR as TAT rises may enhance ED resilience, reduce LOS, and support more predictable patient flow during future outbreaks and surge conditions.

Для цитирования: Chen Cheng-Han, Lee Yi-Tzu, Li Li-Hua, Hsu Teh-Fu, How Chorng-Kuang, Cheng Chao-Min. Capacity-Responsive COVID-19 Testing Performance in Emergency Departments: Turnaround Time Thresholds for Lateral Flow Assay and Polymerase Chain Reaction Strategies.. Prehospital and disaster medicine. 2026. DOI: 10.1017/s1049023x26108930.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.