MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6an00114a

Медицинская библиотека · The Analyst · 2026

A portable acoustic biosensing platform combined with paper-based capillary fluidics for the rapid detection of antibodies in serum.

Chronaki Dimitra, Grammatikos Stylianos, Ntimtsas Angelos, Matsis Marios, Kokolakis Orestis F, Alexaki Konstantina, Pournara Zoi, Tsortos Achilleas, Zafiropoulos Alexandros, Gizeli Electra

СтатьяПеревод пока не подготовлен

Аннотация

We report the development of a sensitive biosensing platform based on a shear-horizontal surface acoustic wave (SH-SAW) device and paper fluidics, with the potential to be used outside centralized laboratory settings. Systematic research on the biorecognition surface, blocking agent, fluidics and measuring unit allowed us to transform a laboratory-based method into a field-deployable device. As a proof-of-concept, the platform was used for the detection of SARS-CoV-2 anti-spike antibodies on a surface-immobilized spike protein, tested in both simulated and human blood serum samples. A poly-L-lysine (PLL) layer was selected as a biocompatible surface for spike protein immobilization; the polymer layer can be easily removed through gentle mechanical rubbing, allowing regeneration and multiple uses of the sensing device. This surface, combined with novel paper-based capillary fluidics, enabled real-time monitoring of spike antibody binding via acoustic wave phase measurements in the range of 1-100 nM antibodies in 1% v/v serum. Further acoustic wave amplitude amplification and a tenfold improvement in the detection limit (0.1 nM) were achieved by the use of gold nanoparticles conjugated with a secondary antibody. This optimized assay was successfully evaluated in a small pilot clinical study of 20 patient samples. Our new SH-SAW immunosensor exhibited sensitivity and specificity comparable to commercial systems with standard fluidics and instrumentation; importantly, its limit of detection is better than the clinically relevant value of ∼11 RU mL-1. This portable, low-cost platform, combining a pocket-size network analyzer with disposable paper fluidics and a regenerable sensing surface, offers a promising solution for quantitative antibody detection near or at the point-of-care.

Для цитирования: Chronaki Dimitra, Grammatikos Stylianos, Ntimtsas Angelos, Matsis Marios, Kokolakis Orestis F, Alexaki Konstantina, Pournara Zoi, Tsortos Achilleas, Zafiropoulos Alexandros, Gizeli Electra. A portable acoustic biosensing platform combined with paper-based capillary fluidics for the rapid detection of antibodies in serum.. The Analyst. 2026. DOI: 10.1039/d6an00114a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.