MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00604-026-07918-7

Медицинская библиотека · Mikrochimica acta · 2026

A smartphone-integrated aptasensor for SARS-CoV-2 S1 protein using multi-walled carbon nanotube-ionic liquid modified electrodes.

Senturk Huseyin, Erdem Arzum

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

An aptamer-based electrochemical biosensor was developed for the highly sensitive detection of SARS-CoV-2 S1 protein using electrodes modified with a multi-walled carbon nanotube–ionic liquid (MWCNT–IL) composite. Comprehensive electrochemical and microscopic characterizations of the MWCNT–IL material were conducted, followed by the optimization of experimental parameters including ionic liquid concentration and surface modification time. Critical parameters for aptasensor construction, aptamer concentration, immobilization time, and aptamer-protein interaction time, were also optimized. Under optimal conditions, the biosensor exhibited a wide linear response from 1 fg/mL to 1 ng/mL in buffer, with a remarkably low limit of detection (LOD) of 0.11 fg/mL. Selectivity evaluations against hemagglutinin antigen (HA) and MERS-CoV-S1 (MERS) protein confirmed the sensor’s high specificity for SARS-CoV-2 S1 protein. The sensor’s applicability in artificial saliva was also successfully demonstrated, yielding accurate quantification and low detection limits (LOD: 0.16 fg/mL). Recovery studies in artificial saliva demonstrated satisfactory accuracy, with recoveries ranging from 108% to 120% and high reproducibility. Notably, the aptasensor maintained strong selectivity even in the presence of matrix interferents. Furthermore, the potential for point-of-care use was assessed via a smartphone-connected portable potentiostat. This handheld system enabled a linear detection range of 1 fg/mL to 1 ng/mL with a LOD of 0.83 fg/mL. Collectively, these results highlight the MWCNT–IL-based aptasensor as a robust, low-cost, and portable platform for rapid COVID-19 diagnostics, offering considerable promise for deployment in point-of-care and resource-constrained environments.

Для цитирования: Senturk Huseyin, Erdem Arzum. A smartphone-integrated aptasensor for SARS-CoV-2 S1 protein using multi-walled carbon nanotube-ionic liquid modified electrodes.. Mikrochimica acta. 2026. DOI: 10.1007/s00604-026-07918-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.