MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3343/alm.2025.0516

Медицинская библиотека · Annals of laboratory medicine · 2025

Accuracy of an Optical Waveguide-Based Biosensor Antigen-Detection Test for Severe Acute Respiratory Syndrome Coronavirus-2 and Seasonal Influenza Viruses During the Co-circulating Season.

Kato Hideaki, Yoshinaga Nobuko, Ando Naoko, Ko Shundai, Tokita Akifumi, Kawashima Toshifumi, Shoji Akira, Suzuki Yuzo, Kudo Makoto

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Coronavirus disease 2019, caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), and seasonal influenza are responsible for recurring seasonal epidemics. We tested the accuracy of an optical waveguide-based biosensor for detecting SARS-CoV-2 and seasonal influenza viruses in nasal and nasopharyngeal specimens.

METHODS

We consecutively collected 252 nasopharyngeal swabs (NPSs) and 107 nasal specimens from febrile patients with respiratory symptoms who visited two university hospitals and six clinics between January and March 2025. Point-of-care testing data from an optical waveguide-based biosensor test (Rapiim SARS-CoV-2-N/Flu) and a lateral flow test were compared with those obtained using conventional quantitative real-time reverse transcription PCR.

RESULTS

With NPS specimens, the sensitivity and specificity of the Rapiim SARS-CoV-2-N/Flu test were 95.2% and 100%, respectively, for SARS-CoV-2 (98.8% concordance) and 92.3% and 92.2%, respectively, for seasonal influenza viruses (95.2% concordance). When nasal specimens were used, the sensitivity and specificity of the Rapiim SARS-CoV-2-N/Flu test were 93.1% and 98.0%, respectively, for detecting SARS-CoV-2. The sensitivities for detecting SARS-CoV-2 and seasonal influenza were higher than a lateral flow test. The Rapiim SARS-CoV-2-N/Flu test detected SARS-CoV-2 and seasonal influenza viruses at 10 and 6 days after symptom onset, respectively.

CONCLUSIONS

Rapid test with greater accuracy than lateral flow tests that can differentiate between SARS-CoV-2 and influenza were needed. Point of care antigen testing using the optical waveguide-based biosensor yielded higher sensitivity and specificity for detecting SARS-CoV-2 and seasonal influenza viruses in NPS and nasal specimens than conventional tests, enabling differentiation between both types of acute respiratory infections.

Для цитирования: Kato Hideaki, Yoshinaga Nobuko, Ando Naoko, Ko Shundai, Tokita Akifumi, Kawashima Toshifumi, Shoji Akira, Suzuki Yuzo, Kudo Makoto. Accuracy of an Optical Waveguide-Based Biosensor Antigen-Detection Test for Severe Acute Respiratory Syndrome Coronavirus-2 and Seasonal Influenza Viruses During the Co-circulating Season.. Annals of laboratory medicine. 2025. DOI: 10.3343/alm.2025.0516.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.