MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2025.118269

Медицинская библиотека · Biosensors & bioelectronics · 2025

Smart bioelectronic facemask for non-invasive detection of respiratory infections.

Shi Mi, Wang Lirong, Feng Ru, Li Qiang, Zhang Ruiping, Xu Tailin

СтатьяПеревод пока не подготовлен

Аннотация

With the escalating global burden of respiratory infections and their recurrent outbreaks, the development of simple, accurate, and non-invasive point-of-care diagnostic technologies has become an urgent public health priority. In this study, we present a smart bioelectronic facemask designed for noninvasive detection of respiratory pathogens, which facilitates collection of exhaled aerosols and enables rapid, highly sensitive, and accurate detection of SARS-CoV-2. This platform incorporates flexible microfluidic chip and a miniaturized circuit boards into conventional face masks without compromising user comfort. The microfluidic chip integrates a porous polycarbonate (PC) membrane for continuous aerosol sampling, and a recombinase polymerase amplification (RPA)-coupled electrochemical biosensor for specific viral detection. This wearable platform seamlessly integrates the entire workflow of exhaled aerosol collection, lysis, nucleic acid amplification, and real-time detection, which enables the completion of analysis within 30 min and achieves a detection limit as low as 0.19 copy/μL. Validation using simulated exhaled breath samples demonstrated 96.7 % accuracy, 95.0 % sensitivity, and 100 % specificity compared to RT-qPCR. By combining non-invasive sampling and wearable molecular diagnostics, this smart bioelectronic facemask constitutes a viable platform for point-of-care pathogen detection, offering a timely and practical solution for use in high-risk and resource-limited settings.

Для цитирования: Shi Mi, Wang Lirong, Feng Ru, Li Qiang, Zhang Ruiping, Xu Tailin. Smart bioelectronic facemask for non-invasive detection of respiratory infections.. Biosensors & bioelectronics. 2025. DOI: 10.1016/j.bios.2025.118269.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.