bioRxiv : the preprint server for biology · 2025
Bayesian multi-state multi-condition modeling of a protein structure based on X-ray crystallography data.
СтатьяПрепринтНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hancock Matthew, Holton James, Fraser James S, Adams Paul D, Sali Andrej
Аннотация
An atomic structure model of a protein can be computed from a diffraction pattern of its crystal. While most crystallographic studies produce a single set of atomic coordinates, the billions of protein molecules in a crystal sample many conformational modes during data collection. As a result, a 'multi-state' model that depicts these conformations could reproduce the X-ray data better than a single conformation, and thus likely be more accurate. Computing such a multi-state model is challenging due to a lower data-to-parameter ratio than that for single-state modeling. To address this challenge, additional information could be considered, such as X-ray datasets collected for the same system under distinct experimental conditions (eg, temperature, ligands, mutations, and pressure). Here, we develop, benchmark, and illustrate MultiXray: Bayesian multi-state multi-condition modeling for X-ray crystallography. The input information is several X-ray datasets collected under distinct conditions and a molecular mechanics force field. The model consists of an independent coordinate set for each of several states and the weight of each state under each condition. A Bayesian posterior model density quantifies the match of the model with all X-ray datasets and the force field. A sample of models is drawn from the posterior model density using biased molecular dynamics (MD) simulations. We benchmark MultiXray on simulated CypA X-ray data. Using a second X-ray dataset improves the R free from 0.105 to 0.089. We then demonstrate MultiXray on experimental temperature-dependent data for SARS-CoV-2 Mpro. Using multiple X-ray datasets improves R free of the PDB-deposited structure from 0.253 to 0.237. MultiXray is implemented in our open-source Integrative Modeling Platform (IMP) software, relying on integration with Phenix, thus making it easily applicable to many studies.