MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-026-10266-y

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026

Validation of a modular low-fidelity training model for biportal endoscopic spine surgery.

Niederhauser Camille, Haering Guillaume, Pellegrini Blaise, Ben Rayana Elias, Paravina Sara, Lotfinejad Nasim, Messerer Mahmoud, Barges-Coll Juan, Rothenfluh Dominique

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Spinal endoscopy is associated with a steep learning curve, in part owing to its limited depth perception, which increases the need for training models. This study aimed to investigate construct and predictive validity of the Endobox as a low-fidelity training model for biportal endoscopy.

METHODS

To assess construct validity, we compared the performances of expertsand novices across four Endobox exercises. Performances were evaluated based on completion time and number of attempts, using a 0º endoscope and rongeur. To assess predictive validity of the Endobox, 16 students (n = 8 per group) were randomly assigned into EB+ (twelve training sessions) or EB- (no training) before performing six simulated discectomies on a non-anatomical simulation model. Completion time, technical skill (modified version of the ASSET score), and cognitive demand (NASA-TLX score) were compared. Statistical analysis was carried out using parametric and non-parametric tests using Stata 18 for Mac.

RESULTS

Construct validity: experts were significantly faster in 3/4 exercises (2. p = 0.02, 3. p = 0.01, 4. p = 0.03), except in exercise 1 (p = 0.43). Experts needed fewer attempts for exercises 3 (p = 0.04) and 4 (p = 0.02), rated most difficult (9/10, 8/10 respectively). Predictive validity: the EB+ group was faster (p < 0.001) and improved across all observations, achieving higher scores for safety (p = 0.007), camera/bimanual dexterity, instrument handling, depth perception, and procedure quality (all p < 0.001). No difference in cognitive load was observed (p = 0.621).

CONCLUSION

The present study provides preliminary evidence that the Endobox model may develop skills that are relevant to, and potentially transferable to, a simulated procedure representing endoscopic spine surgery.

Для цитирования: Niederhauser Camille, Haering Guillaume, Pellegrini Blaise, Ben Rayana Elias, Paravina Sara, Lotfinejad Nasim, Messerer Mahmoud, Barges-Coll Juan, Rothenfluh Dominique. Validation of a modular low-fidelity training model for biportal endoscopic spine surgery.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2026. DOI: 10.1007/s00586-026-10266-y.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.