MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm15145356

Медицинская библиотека · Journal of clinical medicine · 2026

Artificial Intelligence and Endobronchial Ultrasound for Lymph-Node Detection and Characterization: A Pioneer Multicenter Transatlantic Study.

Mascarenhas Miguel, Nuevo Gema Diaz, Lopes Sara, Sancho Juan Puertas, Garcia-Gallo Cristina Lopez, Oliveira Luiza Bicudo de, Chinzon Miriam, Assis Larissa Mercadante de, Ejima Gustavo, Maluf-Filho Fauze, Carvalho Matheus Ferreira, Dias Thomás Paiva Lima, Chirichela Isabele Alves, Ribeiro Tiago, Mendes Francisco, Pérez Ana, Agudo Castillo Belén, Costa António Pinto da, González-Haba Mariano, Fonseca João, Macedo Guilherme, Moura Eduardo Guimarães Hourneaux De, Ferreira João Pedro, Brito João Marcelo Lopes Toscano de, Machuca Tiago Noguchi, Scordamaglio Paulo Rogério, Oliveira Felipe Nominando Diniz, Leite-Moreira Adelino F

СтатьяПеревод пока не подготовлен

Аннотация

Background/

Objectives

Accurate mediastinal and hilar lymph node (LN) assessment is central to lung cancer staging and treatment selection. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has become the standard minimally invasive procedure for mediastinal staging, enabling real-time identification, characterization and sampling of LNs. Although effective, this technique remains operator dependent, and subject to interobserver variability. This study aims to report the development of a Vision Transformer-based AI model for automatic LN detection and classification on EBUS images.

Methods

A multicenter, multidevice, retrospective study, using EBUS images of three referral centers (Spain and Brazil). The dataset included images of patients with benign and malignant LNs. Bounding-box annotations were applied for LN localization, and LNs were classified as benign or malignant according to histopathologic reference standards. Detection performance was evaluated with mean average precision, at an intersection over union threshold of 0.5 (mAP50). Characterization performance was assessed using accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC).

Results

The dataset included 6492 images from 27 patients, of whom 16 had malignant LNs. In the test set, the model achieved a mAP50 of 0.79 for LN detection. For malignant characterization, the model achieved an accuracy of 90.6%, sensitivity of 85.4%, and an AUROC of 0.938.

Conclusions

The results of this study support the feasibility of AI-assisted EBUS interpretation for nodal staging workflows and raise the possibility that AI-assisted EBUS could enhance diagnostic performance, while reducing operator variability. Larger prospective studies are needed before clinical implementation.

Для цитирования: Mascarenhas Miguel, Nuevo Gema Diaz, Lopes Sara, Sancho Juan Puertas, Garcia-Gallo Cristina Lopez, Oliveira Luiza Bicudo de, Chinzon Miriam, Assis Larissa Mercadante de, Ejima Gustavo, Maluf-Filho Fauze, Carvalho Matheus Ferreira, Dias Thomás Paiva Lima, Chirichela Isabele Alves, Ribeiro Tiago, Mendes Francisco, Pérez Ana, Agudo Castillo Belén, Costa António Pinto da, González-Haba Mariano, Fonseca João, Macedo Guilherme, Moura Eduardo Guimarães Hourneaux De, Ferreira João Pedro, Brito João Marcelo Lopes Toscano de, Machuca Tiago Noguchi, Scordamaglio Paulo Rogério, Oliveira Felipe Nominando Diniz, Leite-Moreira Adelino F. Artificial Intelligence and Endobronchial Ultrasound for Lymph-Node Detection and Characterization: A Pioneer Multicenter Transatlantic Study.. Journal of clinical medicine. 2026. DOI: 10.3390/jcm15145356.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.