MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1364/oe.599644

Медицинская библиотека · Optics express · 2026

Ultrasensitive and broadband micro-ring based optomechanical ultrasound sensor for photoacoustic imaging.

Xu Chao, Zhao Zijie, Chen Xu, Wang Shuxiao, Wang Wei, Wang Chenxi, Shen Jian, Li Zhuoyun, Yue Wencheng, Gao Hang, Cai Yan

СтатьяПеревод пока не подготовлен

Аннотация

Recent advances in ultrasonography and photoacoustic tomography call for ultrasound sensors with high sensitivity, broad bandwidth, miniaturized footprint, and scalability. A conventional piezoelectric transducer is fundamentally constrained by limited sensitivity, element density, and system integration complexity. In this work, we introduce a micro-ring based optomechanical ultrasound sensor using a SiN/Si hybrid waveguide structure with a 30 nm air gap engineered within the sensing region. The micro-ring resonator exhibits a high-quality factor of 4.8 × 104 and a free spectral range (FSR) of 18 nm at the wavelength of 1580 nm. With a compact diameter of 18 µm, the sensor achieves a low noise-equivalent pressure below 0.64 mPa Hz-1/2 over a frequency range of 2-30 MHz, which is two orders of magnitude better than piezoelectric devices of the same size. Furthermore, the device enables photoacoustic signal detection at a depth up to 10 cm and offers a wide acceptance angle of ±20° for frequencies up to 20 MHz. High-resolution photoacoustic tomography of a graphite pencil lead is demonstrated, revealing sub-millimetric structural details. With its exceptional sensitivity, broad bandwidth, and inherent compatibility with chip-scale multiplexing, this platform offers a promising solution for minimally invasive photoacoustic endoscopy, high-resolution imaging systems, and highly dense ultrasound sensor networks.

Для цитирования: Xu Chao, Zhao Zijie, Chen Xu, Wang Shuxiao, Wang Wei, Wang Chenxi, Shen Jian, Li Zhuoyun, Yue Wencheng, Gao Hang, Cai Yan. Ultrasensitive and broadband micro-ring based optomechanical ultrasound sensor for photoacoustic imaging.. Optics express. 2026. DOI: 10.1364/oe.599644.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.