MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-026-12741-5

Медицинская библиотека · Surgical endoscopy · 2026

Toward augmented reality in laparoscopic liver surgery using electromagnetic tracking: a clinical feasibility study.

Olthof Karin A, Venix Lisanne P J, Pruijt Maaike, den Hartog Anne G, Kok Niels F M, Ruers Theo J M, Fusaglia Matteo, Kuhlmann Koert F D

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Augmented reality (AR) has the potential to enhance intraoperative visualization, orientation and precision in laparoscopic liver surgery by combining preoperative imaging data with surgical reality. Accurate registration and motion compensation remain significant challenges for clinical implementation. This study aims to translate electromagnetic (EM)-tracked navigation to the laparoscopic setting, incorporate AR and assess clinical feasibility and accuracy.

METHODS

The open navigation workflow was adapted by implementing EM tracking for a pointer, laparoscopic ultrasound (LUS) probe, and laparoscope. Four AR visualization modes were developed and tested ex vivo on a liver phantom; seven hepatobiliary surgeons rated essential anatomical structures and the preferred display modes. A prospective feasibility study was conducted in patients undergoing laparoscopic liver resection. An EM sensor was attached to the liver surface, landmark-based registration was performed using tracked LUS and pointer, and AR overlays were displayed intraoperatively. Outcomes included technical feasibility of the surgical workflow, registration accuracy and intraoperative AR performance.

RESULTS

The translation of the EM navigation workflow to the laparoscopic setting yielded robust tracking performance across all laparoscopic instruments. Surgeons rated the tumor, hepatic veins, and portal veins as the most important structures for AR visualization and preferred displays emphasizing a resection plane with target structures and applying depth shading to improve depth perception. The complete workflow (i.e., sensor attachment, registration and AR visualization) was achieved in 13 of 14 procedures without device-related complications. Mean target registration error was 6.3 ± 3.8 mm and registration took an average of 11 ± 7 min.

CONCLUSIONS

AR navigation during laparoscopic liver surgery using EM tracking is feasible and enables organ tracking including local motion compensation. This workflow supports intraoperative orientation and tumor localization in minimally invasive resections potentially improving clinical outcome.

Для цитирования: Olthof Karin A, Venix Lisanne P J, Pruijt Maaike, den Hartog Anne G, Kok Niels F M, Ruers Theo J M, Fusaglia Matteo, Kuhlmann Koert F D. Toward augmented reality in laparoscopic liver surgery using electromagnetic tracking: a clinical feasibility study.. Surgical endoscopy. 2026. DOI: 10.1007/s00464-026-12741-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.