MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/rcs.70188

Медицинская библиотека · The international journal of medical robotics + computer assisted surgery : MRCAS · 2026

Structural Design and Optimisation of a Semi-Direct-Drive Master Manipulator.

Han Rui, Sang Hongqiang, Liu Fen

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In recent years, laparoscopic surgical robots have rapidly developed. However, research on master manipulators remains relatively limited. Existing designs are often characterised by structural complexity and inadequate force feedback capabilities.

METHODS

A semi-direct-drive serial 8-degree of freedom force-feedback master manipulator was developed. A global fluctuation performance index based on mean absolute deviation and a minimum gravity torque index were proposed, and structural optimisation was performed using a multi-objective genetic algorithm. A spring-cable gravity compensation mechanism was also designed.

RESULTS

The optimised manipulator satisfied laparoscopic surgical requirements, improved the comprehensive performance index by 93.63%, reduced motor output torque by about 70%, and decreased the maximum end-effector force and torque from 15.420 N to 0.123 Nm to 1.402 N and 0.034 Nm, respectively.

CONCLUSION

The proposed master manipulator demonstrates potential application value in the field of laparoscopic surgical robots.

Для цитирования: Han Rui, Sang Hongqiang, Liu Fen. Structural Design and Optimisation of a Semi-Direct-Drive Master Manipulator.. The international journal of medical robotics + computer assisted surgery : MRCAS. 2026. DOI: 10.1002/rcs.70188.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.