DOI 10.3390/diagnostics16081188
Discordance Between Conventional Ultrasound and Transient Elastography in Hepatic Steatosis Assessment: Clinical Factors Associated with Discrepant Findings.
Аннотация
Background
Discrepancies are frequently observed between liver steatosis grading assessed by conventional B-mode ultrasonography and vibration-controlled transient elastography (VCTE) with controlled attenuation parameter (CAP). This study aimed to identify factors associated with these differences and to evaluate whether the two imaging methods provide comparable steatosis classifications.
Methods
We conducted a retrospective cross-sectional observational study including 130 hospitalized patients evaluated over a two-year period who underwent laboratory testing, abdominal ultrasonography, and transient elastography. The analyzed variables included demographic characteristics, nutritional status, comorbidities, and biochemical parameters such as alanine aminotransferase (ALAT), total cholesterol, triglycerides, gamma-glutamyl transferase (GGT), and the fibrosis-4 index (FIB-4). Patients were classified into two groups: concordant steatosis grading between the two methods (n = 61) and discordant results (n = 69).
Results
Concordant steatosis grading was more frequently observed in patients with serum total cholesterol > 200 mg/dL (45.9%) and FIB-4 values between 1.45-3.25 (44.2%). A trend toward higher concordance was also observed in patients with elevated triglycerides. In contrast, viral liver disease was significantly associated with discordant results (26.2%). Higher fibrosis stages assessed by VCTE (F ≥ 2) and FIB-4 values > 3.25 showed a non-significant trend toward discordance.
Conclusions
Several clinical and biochemical factors influence the agreement between ultrasound and VCTE-based CAP in the assessment of hepatic steatosis. Elevated cholesterol and intermediate FIB-4 values were associated with concordant results, whereas viral liver disease was associated with discordance between the two imaging modalities.