MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.70115

Медицинская библиотека · Veterinary surgery : VS · 2026

3D printed patient-specific drill guide for percutaneous pedicle screw fixation in lumbosacral vertebrae in dogs: A cadaveric study and clinical case report.

Yeom Kyuhyun, Yoon Jongpil, Jeon Youngjin, Lee Haebeom, Jeong Jaemin

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the feasibility, accuracy, and safety of percutaneous pedicle screw fixation (PPSF) in the canine lumbosacral junction using three-dimensional (3D)-printed patient-specific drill guides (PSGs).

STUDY

DESIGN

Cadaveric study and clinical case report.

SAMPLE POPULATION: A total of 13 Beagle cadavers and one 5-year-old German Shepherd.

METHODS

In each cadaver, one side underwent 3D-PSG-assisted PPSF by a novice surgeon and freehand PPSF on the contralateral side by an experienced surgeon. Outcomes included operative time (min), fluoroscopic counts, incision length (mm), vertebral canal breach (grade 0-2; grade 2 defined as relevant), and angular deviation (degrees). The clinical case underwent unilateral biportal endoscopy laminectomy and discectomy followed by 3D-PSG-assisted PPSF.

RESULTS

Operative times were comparable (PSG: 22.65 ± 2.71 min; freehand: 24.82 ± 5.00 min; p = .139). Fluoroscopic acquisitions were fewer with 3D-PSG (median 5 [5-8]) than freehand (9 [7-14]; p = .003). At L7, canal breach occurred in 1/13 (PSG) and 6/13 (freehand; p = .073); relevant were 1/1 and 4/6, respectively. At S1, breach rates did not differ: 3/13 (PSG) and 2/13 (freehand; p = 1.000); relevant were 1/3 and 1/2, respectively. Angle deviations at L7 were smaller in the 3D-PSG (sagittal 2.58° and 5.82°, p = .018; transverse 6.4° and 12.8°, p = .036). No significant differences at S1. In the clinical case, minor breaches occurred at L7 left (medial) and S1 right (cranial). The dog exhibited normal gait at 3 months.

CONCLUSION

3D-PSG-assisted PPSF at the canine lumbosacral junction was feasible, with improved screw placement accuracy at L7 and reduced fluoroscopic exposure.

CLINICAL SIGNIFICANCE: 3D-PSGs may standardize screw trajectory control across surgeon experience levels.

Для цитирования: Yeom Kyuhyun, Yoon Jongpil, Jeon Youngjin, Lee Haebeom, Jeong Jaemin. 3D printed patient-specific drill guide for percutaneous pedicle screw fixation in lumbosacral vertebrae in dogs: A cadaveric study and clinical case report.. Veterinary surgery : VS. 2026. DOI: 10.1111/vsu.70115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.