MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bjane.2026.844757

Медицинская библиотека · Brazilian journal of anesthesiology (Elsevier) · 2026

Comparative analysis of a 3D-printed videolaryngoscope versus the Macintosh model in adult airway management: a randomized clinical trial.

Mendes Florentino Fernandes, Immich Liége Caroline, Gross Thiago Fagundes, Braga Luis Fernando Marcelino, Aires Andreia Gomes, Braganhol Elizandra, Magalhães Mendonça Vilela Ramon, Carrazzoni Dos Reis Francine Ullrich, Piva Gustavo Zordan, Gomez Victor Hugo Reinoso, Rodrigues Vinicius Hofstätter, Reguly Afonso, Spinelli Leandro de Freitas, Amaral Simone Schneider, Introíni Gisele Orlandi

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Video Laryngoscopy (VL) provides enhanced glottic visualization in airway management, but its high cost limits adoption. Three-Dimensional (3D) printing offers a cost-effective alternative for producing VL devices. This randomized trial compared a 3D-printed Videolaryngoscope (VL3D) with the standard Macintosh Laryngoscope (MAC) during tracheal intubation in adults.

METHODS

This was a randomized, controlled, and assessor-blinded clinical trial. The primary outcome was intubation difficulty, assessed using the Intubation Difficulty Scale (IDS). Secondary outcomes included glottic visualization (Cormack-Lehane grade) and Intubation Time (IT). The final analysis followed a modified intention-to-treat principle.

RESULTS

This study included 52 patients scheduled to undergo general anesthesia with tracheal intubation. Baseline characteristics were comparable between groups. The analysis included 49 patients (VL3D, n = 26; MAC, n = 23). Categorical analysis of the primary outcome showed a higher incidence of moderate-to-severe intubation difficulty in the VL3D group (23.1% vs. 0%, p = 0.032), although median IDS scores were statistically similar. In relation to secondary outcomes, the VL3D provided significantly superior glottic visualization (Cormack-Lehane grade I: 72.0% in the VL3D group vs. 33.3% in the MAC group, p = 0.002). Conversely, the VL3D was associated with a significantly longer intubation time (median 70 seconds vs. 40 seconds, p = 0.005).

CONCLUSIONS

The VL3D demonstrated superior glottic visualization but correlated with significantly longer intubation duration and greater procedural difficulty. These findings suggest that additional specialized training or design optimization is necessary before widespread clinical implementation.

Для цитирования: Mendes Florentino Fernandes, Immich Liége Caroline, Gross Thiago Fagundes, Braga Luis Fernando Marcelino, Aires Andreia Gomes, Braganhol Elizandra, Magalhães Mendonça Vilela Ramon, Carrazzoni Dos Reis Francine Ullrich, Piva Gustavo Zordan, Gomez Victor Hugo Reinoso, Rodrigues Vinicius Hofstätter, Reguly Afonso, Spinelli Leandro de Freitas, Amaral Simone Schneider, Introíni Gisele Orlandi. Comparative analysis of a 3D-printed videolaryngoscope versus the Macintosh model in adult airway management: a randomized clinical trial.. Brazilian journal of anesthesiology (Elsevier). 2026. DOI: 10.1016/j.bjane.2026.844757.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.