Impact of endoscopic ultrasound-guided fine-needle biopsy on management of suspected small (11-20 mm) and very small (≤10 mm) low-risk nonfunctioning pancreatic neuroendocrine tumors.

Crinó Stefano Francesco, Conti Bellocchi Maria Cristina, Tavian Piero, De Pretis Nicolò, Sina Sokol, Luchini Claudio, Samanta Jayanta, Dhar Jahnvi, Rizzatti Gianenrico, Palumbo Giulia, Larghi Alberto, Spada Cristiano, Facciorusso Antonio, D'Onofrio Mirko, Salvia Roberto, Paiella Salvatore, Frulloni Luca, Landoni Luca

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The role of routine endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of small (≤20 mm) nonfunctioning pancreatic neuroendocrine tumors (NF-PanNETs) remains debated. We evaluated the impact of EUS-FNB on clinical management of very small (≤10 mm) and small (11-20 mm) suspected NF-PanNETs in patients who were otherwise suitable for active surveillance.

METHODS

This was a retrospective analysis of patients with single, sporadic, ≤20-mm lesions, exhibiting typical imaging features of NF-PanNET, who were referred for EUS-FNB at two high-volume centers (January 2017-December 2024). The primary outcome was impact of EUS-FNB on management (a diagnosis leading to a strategy other than active surveillance). Secondary outcomes included factors associated with substantial management change, sample adequacy, safety, Ki-67 assessment, and concordance between EUS-FNB and surgical grading.

RESULTS

417 lesions (160 [very small]; 257 [small]) were included. EUS-FNB changed management in 68 cases (16.3%), more frequently in small lesions (19.8% vs. 10.6%; P = 0.01). A substantial impact leading to surgical resection was more frequent in small lesions (12.4% vs. 3.7%; P = 0.002). Lesion size 11-20 mm was independently associated with substantial impact (odds ratio 3.19, 95%CI 1.05-9.66). Sample adequacy was 96.1%, adverse event rate was 3.4%, Ki-67 was feasible in 96.0% of confirmed PanNETs, and grading concordance with surgical specimens was 78.1%.

CONCLUSIONS

In patients with suspected small NF-PanNET without suspicious features, EUS-FNB provided a clear clinical benefit for larger lesions (11-20 mm). For very small lesions (≤10 mm), its more limited impact supports individualized, shared decision making with the patient.

Для цитирования: Crinó Stefano Francesco, Conti Bellocchi Maria Cristina, Tavian Piero, De Pretis Nicolò, Sina Sokol, Luchini Claudio, Samanta Jayanta, Dhar Jahnvi, Rizzatti Gianenrico, Palumbo Giulia, Larghi Alberto, Spada Cristiano, Facciorusso Antonio, D'Onofrio Mirko, Salvia Roberto, Paiella Salvatore, Frulloni Luca, Landoni Luca. Impact of endoscopic ultrasound-guided fine-needle biopsy on management of suspected small (11-20 mm) and very small (≤10 mm) low-risk nonfunctioning pancreatic neuroendocrine tumors.. Endoscopy. 2026. DOI: 10.1055/a-2863-1084.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.