Predictive value of simple echocardiographic parameters for screening pulmonary hypertension under the revised definition: a study for general hospitals.
Аннотация
BACKGROUND
The current guideline recommends a peak tricuspid regurgitation velocity (TRV) ≥2.9 m/s on echocardiography for pulmonary hypertension (PH) screening; however, this threshold was based on the previous PH definition (mean pulmonary arterial pressure (mPAP) ≥25 mm Hg) and derived largely from PH referral centres.
METHODS
We retrospectively analysed 755 patients who underwent both transthoracic echocardiography and right heart catheterisation at two general hospitals. The discrimination of peak TRV and estimated right atrial pressure (eRAP), derived from inferior vena cava diameter and respiratory variation, for screening for PH was assessed by receiver operating characteristic curve analysis. Optimal cut-off values were determined with the Youden Index.
RESULTS
The c-statistic for peak TRV in detecting PH was 0.82 (95% CI 0.79 to 0.85). An optimal cut-off of 2.7 m/s provided higher sensitivity (72%) than the conventional 2.9 m/s threshold (60%) while maintaining high specificity (82%). In 681 patients with available TRV and eRAP data, adding eRAP improved discrimination compared with TRV alone (c-statistic 0.83 vs 0.80; net reclassification improvement=0.14, p=0.002). eRAP ≥5 mm Hg was associated with a higher risk of PH, and the combination of elevated TRV and eRAP yielded the strongest association.
CONCLUSION
For screening under the revised PH definition, a peak TRV of 2.7 m/s is suggested as the optimal cut-off. Although TRV alone showed good discriminative performance, combining it with eRAP further improved diagnostic accuracy using simple echocardiographic measures.