MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcmg.2025.11.011

Медицинская библиотека · JACC. Cardiovascular imaging · 2026

Deep Learning and Fluid Dynamics On-Site CT-FFR Solution Compared to Off-Site FFRct and Invasive FFR.

Fazzari Fabio, Khenkina Natallia, Piccinni Giulia, Biroli Matteo, Annoni Andrea, Berna Giovanni, Cannata Francesco, Carerj Maria Ludovica, Celeste Fabrizio, Del Torto Alberico, Formenti Alberto, Frappampina Antonio, Fusini Laura, Gripari Paola, Ghulam Alì Sarah, Junod Daniele, Maltagliati Anna, Mancini Maria Elisabetta, Mantegazza Valentina, Maragna Riccardo, Marchetti Francesca, Sbordone Francesco Paolo, Stankowski Kamil, Tassetti Luigi, Volpe Alessandra, La Grutta Ludovico, Carafiello Gianpaolo, Laghi Andrea, Guaricci Andrea Igoren, De Marco Federico, Galli Stefano, Trabattoni Daniela, Montorsi Piero, Pedrinelli Roberto, Sinagra Gianfranco, Filardi Pasquale Perrone, Baggiano Andrea, Muratori Manuela, Pergola Valeria, Mushtaq Saima, Pontone Gianluca, Italian Society of Cardiology (SIC) Working Group on Cardiac CT and Nuclear Cardiology

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

On-site computed tomography (CT)-derived fractional flow reserve (FFR) solutions are increasingly needed to reduce delays, costs, and reliance on external platforms.

OBJECTIVES

This single-center prospective study evaluated the diagnostic performance of an on-site deep learning and fluid dynamic-based CT-FFR algorithm (xFFR, GE HealthCare) against off-site HeartFlow CT-FFR (FFRct) and invasive FFR (iFFR) for coronary artery disease (CAD) assessment.

METHODS

In this single-center prospective study, 250 symptomatic patients at intermediate-to-high CAD risk (mean age: 65 ± 9 years; 76% male) underwent coronary computed tomography angiography (CTA), xFFR, FFRct, and invasive coronary angiography with iFFR. Areas under the curve (AUCs) were calculated for xFFR and FFRct, with Spearman's correlations and Cohen's κ used to assess agreement with iFFR.

RESULTS

Functionally significant CAD was detected in 56.6% (xFFR), 54% (FFRct), and 48% (iFFR) of cases; xFFR showed sensitivity, specificity, and accuracy of 95%, 81%, and 88%, respectively. The overall diagnostic accuracy was comparable to FFRct (AUC: 0.91 vs AUC: 0.89; P = 0.274), superior only for left anterior descending coronary artery assessment (AUC: 0.96 vs AUC: 0.84; P = 0.001). Correlation analysis showed good agreement with iFFR (ρ = 0.67) and FFRct (ρ = 0.53). The mean xFFR analysis time was 8 ± 3.4 minutes.

CONCLUSIONS

This study establishes xFFR as a robust and efficient on-site tool for assessing CAD, demonstrating high diagnostic accuracy, reproducibility, and agreement with invasive methods. Its rapid processing and integration into clinical workflows position xFFR as a promising alternative to off-site FFRct solutions. Further studies are warranted to confirm its generalizability and optimize its implementation.

Для цитирования: Fazzari Fabio, Khenkina Natallia, Piccinni Giulia, Biroli Matteo, Annoni Andrea, Berna Giovanni, Cannata Francesco, Carerj Maria Ludovica, Celeste Fabrizio, Del Torto Alberico, Formenti Alberto, Frappampina Antonio, Fusini Laura, Gripari Paola, Ghulam Alì Sarah, Junod Daniele, Maltagliati Anna, Mancini Maria Elisabetta, Mantegazza Valentina, Maragna Riccardo, Marchetti Francesca, Sbordone Francesco Paolo, Stankowski Kamil, Tassetti Luigi, Volpe Alessandra, La Grutta Ludovico, Carafiello Gianpaolo, Laghi Andrea, Guaricci Andrea Igoren, De Marco Federico, Galli Stefano, Trabattoni Daniela, Montorsi Piero, Pedrinelli Roberto, Sinagra Gianfranco, Filardi Pasquale Perrone, Baggiano Andrea, Muratori Manuela, Pergola Valeria, Mushtaq Saima, Pontone Gianluca, Italian Society of Cardiology (SIC) Working Group on Cardiac CT and Nuclear Cardiology. Deep Learning and Fluid Dynamics On-Site CT-FFR Solution Compared to Off-Site FFRct and Invasive FFR.. JACC. Cardiovascular imaging. 2026. DOI: 10.1016/j.jcmg.2025.11.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.