DOI 10.1016/j.jcct.2025.12.007
Novel deep learning CCTA-FFR for detecting functionally significant coronary stenosis: Comparison with iFR.
Аннотация
BACKGROUND
Deep learning-based fractional flow reserve derived from coronary CT angiography (CT-FFR) enables noninvasive assessment of lesion-specific ischemia. Onsite CT-FFR systems provide near-real-time physiologic evaluation at the workstation, potentially reducing unnecessary invasive testing. This study evaluated the diagnostic performance of a novel onsite deep learning CT-FFR algorithm compared with invasive instantaneous wave-free ratio (iFR).
METHODS
We retrospectively analyzed 44 patients (44 lesions) who underwent clinically indicated coronary CT angiography (CCTA) and invasive iFR. CT-FFR values were generated using an onsite deep learning algorithm (cFFR v6) 1-2 cm distal to visually identified stenoses. Physiologic significance was defined as CT-FFR ≤0.80 or iFR ≤0.89. Diagnostic performance metrics were calculated overall and within CCTA stenosis strata (<50 %, 50-70 %, >70 %). ROC analysis and Pearson correlation assessed discriminative ability and linear association. Additional comparative analyses evaluated diagnostic accuracy of CCTA ≥50 % and ≥70 % thresholds relative to iFR and quantified incremental diagnostic value of CT-FFR over CCTA alone.
RESULTS
Of 44 lesions, 28 (63.6 %) were iFR-positive and 30 (68.2 %) were CT-FFR-positive. CT-FFR demonstrated a sensitivity of 89.3 %, specificity of 68.8 %, positive predictive value of 83.3 %, negative predictive value of 78.6 %, and accuracy of 81.8 %; the area under the ROC curve was 0.79 (95 % CI, 0.66-0.92). CT-FFR and iFR showed a modest but significant correlation (r ≈ 0.37). Performance remained favorable in moderate (40-70 %) stenoses (AUC 0.73) and severe (>70 %) stenoses (AUC 0.84). In contrast, CCTA ≥50 % and ≥70 % thresholds showed limited discriminatory ability versus iFR (AUC 0.44 and 0.52, respectively). Compared with CCTA alone, CT-FFR improved both sensitivity and specificity and substantially increased AUC across both thresholds.
CONCLUSION
The onsite deep learning CT-FFR algorithm demonstrated good diagnostic agreement with invasive iFR and maintained performance across stenosis severity categories, while providing clear incremental value over CCTA stenosis assessment alone. These findings support the feasibility of rapid, workstation-integrated physiologic assessment during CCTA interpretation. Larger multicenter studies are needed to validate these results and clarify the clinical role of onsite CT-FFR.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.