DOI 10.3760/cma.j.cn112148-20231031-00401
[The effect of transcatheter edge-to-edge repair on right ventricular reverse remodeling in patients with severe tricuspid regurgitation].
Аннотация
Objective
To quantitatively analyze right ventricular reverse remodeling in patients with severe tricuspid regurgitation after transcatheter tricuspid edge-to-edge repair (T-TEER) by two-dimensional speckle tracking echocardiography, and to preliminarily evaluate the clinical efficacy of this procedure.
Methods
This study was a prospective single-center cohort study. Patients diagnosed with severe tricuspid regurgitation at the Xiamen Cardiovascular Hospital Xiamen University from March 2021 to June 2023 were enrolled. All patients underwent transthoracic echocardiography and transesophageal three-dimensional echocardiography before T-TEER, and transthoracic echocardiography at 30 days, 6 months, and 9 months after T-TEER. The primary endpoint was major adverse cardiovascular and cerebrovascular events, including death, stroke, myocardial infarction, reoperation, arrhythmia, and conduction block. Other clinical evaluation indicators included New York Heart Association (NYHA) functional classification and tricuspid regurgitation grade.
Results
A total of 34 patients were enrolled, aged (67.9±9.3) years, and 71% (24/34) were female. The median follow-up duration was 9 months. All patients achieved a reduction of tricuspid regurgitation by ≥2 grades at 9 months after T-TEER, with 79% (27/34) of them having mild to moderate tricuspid regurgitation. Transthoracic echocardiography at 9 months after T-TEER showed that the vena contracta width of tricuspid regurgitation ((5.42±2.33) mm vs. (11.54±4.05) mm, P<0.001), effective regurgitant orifice area ((0.24±0.09) cm² vs. (0.52±0.14) cm², P<0.001), regurgitant jet area ((7.95±4.02) cm² vs. (13.93±6.10) cm², P<0.001), inferior vena cava diameter ((19.38±2.63) mm vs. (23.56±3.31) mm, P<0.001), right ventricular end-diastolic diameter ((28.03±6.26) mm vs. (33.21±8.24) mm, P=0.001), and tricuspid annular diameter ((36.47±4.40) mm vs. (41.44±7.08) mm, P<0.001) were all reduced compared with baseline; while the tricuspid annular plane systolic excursion ((18.08±5.25) mm vs. (14.91±3.42) mm, P=0.005) and right ventricular fractional area change ((37.61±7.52)% vs. (30.79±9.06)%, P=0.004) were both increased compared with baseline. At 9 months after T-TEER, all patients had a NYHA functional classification of grade Ⅰ or Ⅱ, and no major adverse cardiovascular and cerebrovascular event occurred during the follow-up period.
Conclusion
It is preliminarily confirmed that T-TEER is safe and effective in the treatment of severe tricuspid regurgitation, with significant right ventricular reverse remodeling observed in patients at 9 months after T-TEER.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.