MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5114/aic.2025.154164

Медицинская библиотека · Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2025

Comparison of safety and efficiency of aortic balloon valvuloplasty performed in a free-standing catheterization laboratory and one with cardiac surgery backup.

Janas Adam, Fil Wojciech, Klocek Konrad, Ciekot Katarzyna, Mazur Marta, Synak Magdalena, Kaźmierczak Paweł, Kachel Mateusz, Wojakowski Wojciech, Buszman Piotr, Milewski Krzysztof

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Balloon aortic valvuloplasty (BAV) is typically performed in hybrid theaters or hospitals with cardiosurgery wards. Due to limited access to these facilities, BAV may also be conducted in standalone catheterization laboratories (ASC).

AIM: This study compared the safety and efficiency of BAV in ASC versus cardiac surgery-backed units (CSBU).

MATERIAL AND

METHODS

This multicenter (7 sites) retrospective registry included 514 symptomatic patients with severe aortic stenosis who underwent BAV. Of these, 376 procedures were performed in CSBU and 138 in ASC.

RESULTS

Baseline characteristics were similar, except for a higher prevalence of CAD (ASC 63% vs. CSBU 45%, p = 0.001) and anemia (ASC 47.1% vs. CSBU 11.7%, p = 0.001) in the ASC group. No differences were observed between groups: in-hospital death (ASC 0.72% (n = 1) vs. CSBU 2.93% (n = 11) p = 0.14), tamponades (ASC 0.72% (n = 1) vs. CSBU 1.33% (n = 5) p = 0.57), significant bleeding which required transfusion (ASC 4.34% (n = 6) vs. CSBU 1.86% (n = 7) p = 0.57), pseudoaneurysm (ASC 1.44% (n = 2) vs. CSBU 0.52% (n = 2) p = 0.29) and implanting pacemakers (ASC 4.34% (n = 6) vs. CSBU 1.86% (n = 7) p = 0.57). Balloon dilatation with 18-24 mm diameter balloon catheters reduced the transvalvular gradient in both groups significantly (ASC: 49.6 ±8.2 mm Hg to 34.4 ±5.2 mm Hg, p = 0.01, and CSBU: 50.2 ±7.3 mm Hg to 36.5 ±4.3 mm Hg). There were no significant differences in transvalvular gradient after the procedure.

CONCLUSIONS

The safety and efficiency of BAV performed in standalone catheterization laboratories are comparable to those performed in cardiology wards with cardiac surgery backup.

Для цитирования: Janas Adam, Fil Wojciech, Klocek Konrad, Ciekot Katarzyna, Mazur Marta, Synak Magdalena, Kaźmierczak Paweł, Kachel Mateusz, Wojakowski Wojciech, Buszman Piotr, Milewski Krzysztof. Comparison of safety and efficiency of aortic balloon valvuloplasty performed in a free-standing catheterization laboratory and one with cardiac surgery backup.. Postepy w kardiologii interwencyjnej = Advances in interventional cardiology. 2025. DOI: 10.5114/aic.2025.154164.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.