Deep learning predicts cardiac output from seismocardiographic signals in heart failure.

Wang Jesse, Nouraie Seyed M, Kelly Neil J, Chan Stephen Y

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

BACKGROUND

Determination of cardiac output (CO) is essential to the clinical management of cardiovascular compromise. However, the invasiveness, procedural risks, and reliance on specialized infrastructure limit accessibility and scalability of standard-of-care right heart catheterization (RHC). Seismocardiography (SCG), a non-invasive technique which records subtle chest wall vibrations generated by cardiac mechanical activity, may offer a promising alternative for CO determination.

OBJECTIVES

To develop and evaluate a deep learning model for estimating CO directly from SCG, electrocardiogram (ECG), and body mass index (BMI) in heart failure patients undergoing RHC.

METHODS

We trained a deep convolutional neural network for CO estimation using an open-access dataset comprising 73 heart failure patients with simultaneous RHC, SCG, and ECG recordings. Model performance was evaluated using a rotating leave-pair-out cross-validation strategy.

RESULTS

When estimating CO, the deep learning model achieved a mean bias of -0.35 L/min with limits of agreement (LoA) from -2.21 to 1.51 L/min. When predicting cardiac index in patients with a reference index < 2.2 L/min/m2, the model yielded a mean bias of 0.07 L/min/m2 with LoA from -0.35 to 0.48 L/min/m2.

CONCLUSIONS

This study demonstrates the feasibility of using deep learning in combination with wearable SCG sensors to non-invasively estimate CO. Model performance was particularly strong in low-output states. These findings highlight the potential of SCG-based monitoring to augment clinical decision-making in settings where invasive measurements are impractical or unavailable. Prospective multicenter validation is needed to confirm generalizability and assess clinical impact.

Для цитирования: Wang Jesse, Nouraie Seyed M, Kelly Neil J, Chan Stephen Y. Deep learning predicts cardiac output from seismocardiographic signals in heart failure.. medRxiv : the preprint server for health sciences. 2025. DOI: 10.1101/2025.07.11.25331386.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.