MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.70064

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025

Feasibility and Safety of a Three-Dimensional Sheath for Right Ventricular Septal Endomyocardial Biopsy.

Notaristefano Francesco, Catania Francesco, Del Papa Marco, Freschini Manuel, Russo Giovanni, Barengo Alberto, D'Ammando Matteo, Notaristefano Salvatore, Sforna Stefano, De Gaspari Monica, Rizzo Stefania, Zingarini Gianluca, Verdecchia Paolo, Cavallini Claudio, Basso Cristina, Carluccio Erberto, Sclafani Rocco

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Endomyocardial biopsy (EMB) is a complementary invasive procedure for the diagnosis of several cardiac diseases. New technical developments are needed to increase the safety of the procedure even in low-volume centers.

METHODS

We retrospectively enrolled patients who underwent EMB in our institution, which is a non-heart transplant tertiary care center. Patients were divided into two groups according to the use of a standard long sheath (S-T) or a three-dimensional sheath (3D-T). The latter was originally designed for conduction system pacing.

RESULTS

There were 30 patients in the S-T group and 16 in the 3D-T group. Patients in the 3D-T group were older (65 ± 19 vs. 52 ± 20, p = 0.049) and more likely to have ischaemic heart disease (25% vs. 0%, p = 0.011). Indications for EMB were similar in both groups except for a higher proportion of amyloidosis in the 3D-T group (56% vs. 17%, p = 0.005). The total number of collected samples (10 ± 2 vs. 11 ± 3), their dimensions (1.3 ± 0.6 mm x 1 ± 0.3 mm vs. 1.7 ± 0.6 mm x 1.2 ± 0.4 mm) and the proportion of specimens meeting the quality standard to be analyzed (76% ± 26% vs. 83% ± 25%) didn't differ between 3D-T and S-T (all p = ns). Pericardial effusion or cardiac tamponade was more frequent in the S-T group compared to the 3D-T group (23% vs. 0%, p = 0.078). There were five cardiac tamponades in the S-T group and none in the 3D-T group.

CONCLUSION

The use of a 3D sheath for EMB of the right ventricular septum was feasible and safe with similar diagnostic accuracy compared to the standard long sheath technique.

Для цитирования: Notaristefano Francesco, Catania Francesco, Del Papa Marco, Freschini Manuel, Russo Giovanni, Barengo Alberto, D'Ammando Matteo, Notaristefano Salvatore, Sforna Stefano, De Gaspari Monica, Rizzo Stefania, Zingarini Gianluca, Verdecchia Paolo, Cavallini Claudio, Basso Cristina, Carluccio Erberto, Sclafani Rocco. Feasibility and Safety of a Three-Dimensional Sheath for Right Ventricular Septal Endomyocardial Biopsy.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2025. DOI: 10.1002/ccd.70064.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.