Liver stiffness measurement for non-invasive assessment of central venous pressure in patients with heart failure: A multicentre pilot study.
Аннотация
AIMS: Central venous pressure (CVP) is an important variable in assessing heart failure (HF) patients. However, invasive CVP measurement using right heart catheterization is associated with potential complications, and accurate measurement requires careful attention to technique. In this multicentre pilot study, we aimed to evaluate whether non-invasively measured liver stiffness can be used to assess CVP in patients with HF.
METHODS AND
RESULTS
Patients aged 18 to 85 years with a history of HF (or left ventricular ejection fraction [LVEF] ≤40%) who required central venous line placement with CVP measurement were enrolled in an open-label study. Patients underwent simultaneous invasive catheter CVP measurement and non-invasive liver stiffness measurement (LSM) using vibration-controlled transient elastography (VCTE). The primary endpoint was the agreement between CVP and LSM-derived CVP (-5.9 + 6.8 × ln[LSM]) in the supine position. Among the 38 patients who completed the study, 34 (89.5%) were male, the mean age was 63.8 years, and the median LVEF was 24.5%. CVP correlated with LSM-derived CVP (Spearman r = 0.53, p < 0.001). Bland-Altman analysis demonstrated a mean difference (measured CVP minus LSM-derived CVP) of 0.11 mmHg (95% confidence interval -1.31, 1.54). LSM identified clinically significant CVP elevation (>10 mmHg) with an area under the curve of 0.83. An LSM threshold >10 kPa yielded a sensitivity of 0.73 and a specificity of 0.78, correctly classifying CVP (>10 or ≤10 mmHg) in 76% of patients.
CONCLUSIONS
Liver stiffness measurement is a promising non-invasive surrogate for CVP in patients with HF. Future studies are warranted to validate these findings and to assess the role of LSM for the screening, diagnosis, monitoring, and prognostic stratification of patients with HF.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.