DOI 10.1016/j.jaccas.2025.103397
3- and 4-Dimensional Flow CMR in D-Transposition of the Great Arteries After Atrial Switch Operation.
Аннотация
A 19-year-old man with D-transposition of the great arteries and pulmonary stenosis underwent atrial switch operation and pulmonary valvotomy in infancy. He was lost to follow-up and presented with multiple respiratory infections. An echocardiogram was inconclusive due to poor windows. Cardiac magnetic resonance (CMR) was performed using ferumoxytol 3-dimensional whole heart and 4-dimensional flow pulse sequences, which demonstrated this patient's complex anatomy and physiology. CMR revealed severe pulmonary venous baffle obstruction. A 3-dimensional printed model was created from the CMR and provided key information for planning the complex catheterization approach required to stent the pulmonary venous baffle.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.