MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2024.12.030

Медицинская библиотека · JACC. Cardiovascular interventions · 2025

Transcatheter Tricuspid Valve Replacement With the Novel System: 1-Year Outcomes From the TRAVEL Study.

Pan Xiangbin, Lu Fanglin, Wang Yiwei, Guo Yingqiang, Chen Mao, Meng Xu, Zhang Haibo, Dong Nianguo, Shang Xiaoke, Yang Jian, Liu Yang, Wang Jianan, Liu Xianbao, Guo Huiming, Liu Jian, Qiao Fan, Ascione Guido, Cheung Anson, Modine Thomas, von Bardeleben Ralph Stephan, Granada Juan F, Xu Zhiyun, Hu Shengshou

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter tricuspid valve replacement (TTVR) is emerging as a promising surgical alternative for high-risk patients with tricuspid regurgitation (TR). Nonetheless, the feasibility of more dedicated devices and the need for additional clinical evidence warrant further exploration.

OBJECTIVES

The purpose of this study was to report the 1-year outcomes of the TRAVEL (Transcatheter Right Atrial-Ventricular Valve Replacement With LuX-Valve) study with the LuX-Valve system for patients with severe TR.

METHODS

A total of 126 patients with symptomatic severe TR were prospectively enrolled in the single-arm, multicenter TRAVEL study from June 2020 to August 2021. All patients underwent TTVR via the transatrial approach using the LuX-Valve system. The primary endpoint was all-cause mortality and hospitalization for heart failure at 1-year follow-up. Clinical and echocardiographic outcomes were reported.

RESULTS

At baseline, all enrolled patients (mean age 65.8 ± 7.5 years, 79.4% women) were at high surgical risk (mean Society of Thoracic Surgeons score 9.2% ± 4.4%), with severe or greater TR and NYHA functional class ≥ III. In 1-year follow-up, all-cause mortality was 10.3%, and 4.0% of patients were hospitalized for heart failure. TR was reduced to mild or less in 95.2% (P < 0.001), with decreases in right atrial systolic volume (-38.3 ± 21.7 mL; P < 0.001) and mid right ventricular end-systolic diameter (-6.4 ± 2.3 mm; P < 0.001). NYHA functional class I or II was achieved in 79.8% (P < 0.001), and 6-minute walking distance increased by 71.3 ± 42.8 m (P < 0.001).

CONCLUSIONS

The 1-year outcomes of the TRAVEL study showed a sustained reduction in TR among patients who underwent LuX-Valve TTVR, accompanied by significant right heart reverse remodeling and improved functional status. Favorable procedural success and survival benefits were also demonstrated. (the TRAVEL Trial: Transcatheter Right Atrial-Ventricular Valve Replacement With LuX-Valve; NCT04436653).

Для цитирования: Pan Xiangbin, Lu Fanglin, Wang Yiwei, Guo Yingqiang, Chen Mao, Meng Xu, Zhang Haibo, Dong Nianguo, Shang Xiaoke, Yang Jian, Liu Yang, Wang Jianan, Liu Xianbao, Guo Huiming, Liu Jian, Qiao Fan, Ascione Guido, Cheung Anson, Modine Thomas, von Bardeleben Ralph Stephan, Granada Juan F, Xu Zhiyun, Hu Shengshou. Transcatheter Tricuspid Valve Replacement With the Novel System: 1-Year Outcomes From the TRAVEL Study.. JACC. Cardiovascular interventions. 2025. DOI: 10.1016/j.jcin.2024.12.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.