MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12928-025-01112-x

Медицинская библиотека · Cardiovascular intervention and therapeutics · 2025

Impact of the en face view for coronary cannulation after transcatheter aortic valve replacement.

Mitsui Kentaro, Takagi Kensuke, Kataoka Yu, Ikee Takashi, Murai Kota, Iwai Takamasa, Sawada Kenichiro, Matama Hideo, Honda Satoshi, Tomishima Yoshiyuki, Fujino Masashi, Nakao Kazuhiro, Yoneda Shuichi, Otsuka Fumiyuki, Asaumi Yasuhide, Tsujita Kenichi, Noguchi Teruo

СтатьяПеревод пока не подготовлен

Аннотация

With the increasing number of transcatheter aortic valve replacements (TAVR) performed annually, coronary cannulation in post-TAVR patients has gained importance. The aim of this study was to investigate the effectiveness of the en face view for post-TAVR coronary cannulation. Between March 2015 and March 2024, we evaluated coronary cannulation based on the period when the en face view was initiated post-TAVR in December 2021. To assess the impact of the transcatheter heart valve on cannulation success, we excluded patients whose cannulation was conducted outside the stent frame. During the study period, 82 consecutive coronary cannulations were evaluated (en face era/pre-en face era = 47/35). Balloon-expandable valves were used in 48.8% of cases, and cannulation was performed in 31.7% of cases involving acute coronary syndromes. The overall cannulation success rate was 64.6%. Notably, the success rate was significantly higher during the en face era compared to the pre-en face era (78.7% vs. 45.7%, p = 0.003). Cannulation success was more frequently achieved during the en face era in both types of prostheses (self-expandable valve: 83.3% vs. 50.0%, p = 0.049; balloon-expandable valve: 75.9% vs. 36.4%, p = 0.03). Moreover, multivariate analysis identified the en face era as an independent predictor of cannulation success (adjusted odds ratio = 4.57, 95% confidence interval = 1.37-15.30, p = 0.01). The success rate of cannulation was significantly higher during the en face era. This study suggests that the en face view enhances the success rate of coronary cannulation, regardless of the prosthesis type.

Для цитирования: Mitsui Kentaro, Takagi Kensuke, Kataoka Yu, Ikee Takashi, Murai Kota, Iwai Takamasa, Sawada Kenichiro, Matama Hideo, Honda Satoshi, Tomishima Yoshiyuki, Fujino Masashi, Nakao Kazuhiro, Yoneda Shuichi, Otsuka Fumiyuki, Asaumi Yasuhide, Tsujita Kenichi, Noguchi Teruo. Impact of the en face view for coronary cannulation after transcatheter aortic valve replacement.. Cardiovascular intervention and therapeutics. 2025. DOI: 10.1007/s12928-025-01112-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.