MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s13239-025-00773-2

Медицинская библиотека · Cardiovascular engineering and technology · 2025

Design and Validation of a High-Fidelity Left Atrial Cardiac Simulator for the Study and Advancement of Left Atrial Appendage Occlusion.

Mendez Keegan, Singh Manisha, Willoughby Patrick, Ncho Beatrice, Liao Aileen, Su Susan, Lim Megan, Lee Elijah, Alkhouli Mohamad, Alarouri Hasan, Roche Ellen T

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment. Current benchtop models fail to replicate both anatomical variability and physiological hemodynamics, limiting their utility. This study introduces a novel left atrial cardiac simulator that incorporates patient-derived LAA models within a benchtop circulatory flow loop, enabling high-fidelity LAAO device testing and development.

METHODS

A rigid, patient-derived left atrium (LA) model was 3D printed from segmented MRI data and modified to accommodate attachment of patient-specific LAA models. A library of LAA geometries was fabricated using silicone casting techniques to replicate the mechanical properties of native tissue. The LA-LAA model was integrated into a circulatory flow loop equipped with a pulsatile pump, pressure sensors, and flow probes, allowing real-time hemodynamic analysis. System tunability was demonstrated by varying heart rate, stroke volume, resistance, and compliance to simulate physiological and pathological conditions.

RESULTS

The simulator accurately replicated LA pressure and flow waveforms, closely approximating physiological conditions. Changes in heart rate, stroke volume, and compliance effectively modulated LAP and LA inflow before and after LAAO. Distinct pressure and flow waveforms were observed with different LAA geometries. Hemodynamic analysis revealed increased left atrial pulse pressure after occlusion, with the greatest increase occurring after complete exclusion of the LAA. The simulator facilitated the evaluation of LAAO device performance, including metrics such as seal and PDL, and served as an effective training tool for iterative device deployment and recapture with visual and imaging-guided feedback.

CONCLUSIONS

The left atrial cardiac simulator offers a highly tunable and realistic platform for testing and developing LAAO devices. It also serves as an effective procedural training tool, allowing for the simulation of patient-specific anatomical and hemodynamic conditions. By enabling these advanced simulations, the simulator enhances pre-procedural planning, device sizing, and placement. This innovation represents a significant step toward advancing personalized medicine in atrial fibrillation management and improving LAAO outcomes.

Для цитирования: Mendez Keegan, Singh Manisha, Willoughby Patrick, Ncho Beatrice, Liao Aileen, Su Susan, Lim Megan, Lee Elijah, Alkhouli Mohamad, Alarouri Hasan, Roche Ellen T. Design and Validation of a High-Fidelity Left Atrial Cardiac Simulator for the Study and Advancement of Left Atrial Appendage Occlusion.. Cardiovascular engineering and technology. 2025. DOI: 10.1007/s13239-025-00773-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.