MedElevator Войти в исследования
← Поиск публикаций

DOI 10.25270/jic/24.00234

Медицинская библиотека · The Journal of invasive cardiology · 2025

Outcomes of a transapical edge-to-edge repair system in secondary mitral regurgitation.

Jin Qinchun, Li Wei, Fan Jianing, Lin Dawei, Wen Zilong, Zhang Yuan, Lai Wei, Pan Wenzhi, Zhou Daxin, Ge Junbo

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The ValveClamp system (Hanyu Medical Technology) is a novel transcatheter edge-to-edge repair (TEER) system designed for ease of operation; however, there is a lack of data on its application in secondary mitral regurgitation (SMR). The authors report the mid-term outcomes of TEER using the ValveClamp system in SMR.

METHODS

The study prospectively analyzed consecutive severe SMR patients who underwent transapical ValveClamp implantation at 10 Chinese centers. The enrolled patients were categorized into atrial SMR (aSMR) and ventricular SMR (vSMR) groups. Clinical and echocardiographic outcomes were evaluated at baseline and at follow-up.

RESULTS

A total of 19 aSMR and 24 vSMR patients were enrolled. Technical success was achieved in 100% of the patients and the overall 30-day device success rate was 88.37%. At 1 year, sustained MR reduction to less than or equal to 1+ was achieved in 76.47% of aSMR cases and 77.27% of vSMR cases, and positive reverse left cardiac remodeling was observed. The estimated overall 1-year survival and HF rehospitalization rates for aSMR and vSMR were 83.33% and 83.59%, respectively (log rank P = .98), and improvement of New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire score were observed in both groups. In multivariable logistic analysis, a lower leaflet-to-annulus index (LAI) (odds ratio [OR], 0.021; 95% CI, 0.001-0.042; P = .02) and a narrow MR jet type (OR, 12.029; 95% CI, 1.530-94.592-0.990; P = .02) were independently associated with a higher incidence of a residual MR of at least 2+ at 3 months after TEER.

CONCLUSIONS

TEER using the ValveClamp system is a safe and feasible therapeutic option for patients with SMR regardless of MR etiology. A lower LAI and a narrow MR jet type were independent predictors of residual MR at follow-up.

Для цитирования: Jin Qinchun, Li Wei, Fan Jianing, Lin Dawei, Wen Zilong, Zhang Yuan, Lai Wei, Pan Wenzhi, Zhou Daxin, Ge Junbo. Outcomes of a transapical edge-to-edge repair system in secondary mitral regurgitation.. The Journal of invasive cardiology. 2025. DOI: 10.25270/jic/24.00234.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.