DOI 10.1097/md.0000000000040600
Transcatheter closure of paravalvular leakage through multiple approaches after surgical mechanical valve replacements: A retrospective study.
Аннотация
BACKGROUND
Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.
METHODS
From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation. We reviewed the catheter techniques, perioperative characteristics, and prognosis.
RESULTS
The median follow-up was 28 (3-58) months. The procedure was successful in 60/64 (93.8%) patients. There were 36 aortic PVLs, 27 mitral PVLs, and 1 combined aortic and mitral PVL which were repaired by the transcatheter approach. A total of 24 patients had aortic valve replacements and 20 patients had mitral valve replacements, while 20 patients had previously combined aortic and mitral valve replacements. Procedural time was 35 to 300 (106.6±51.2) minutes. Fluoroscopic time was 8 to 50 (17.6±11.3) minutes. The hospital stay was 5 to 21 (8.1±3.5) days. A total of 47 (78.3%) patients improved by ≥1 New York Heart Association functional class at the 1-year follow-up.
CONCLUSION
Complex catheter techniques were included in percutaneous closure of mechanical PVL. However, this minimally closure treatment could provide reliable outcomes and shorter hospital stays in selected patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало