MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12872-024-04383-z

Медицинская библиотека · BMC cardiovascular disorders · 2025

WATCHMAN versus LACbes® device for percutaneous left atrial appendage closure: a single-center, propensity-matched study.

Zhang Song, Xiong Sihuai, Zhang Sha, Chen Keyu, Wang Hua, Li Ke, Xu Xudong, Zhao Xianxian, Zhu Ni, Huang Xinmiao, Qin Yongwen, Guo Zhifu, Bai Yuan

СтатьяСравнительное исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Different left atrial appendage closure (LAAC) devices have been introduced into the clinical setting. A new dual-seal mechanism LACbes® occluder with isogenous barbs for LAAC has been designed to facilitate easier delivery and improve safety. The purpose of this study is to compare the clinical outcomes of the WATCHMAN with those of the LACbes® device for LAAC.

METHODS

Consecutive patients with atrial fibrillation (AF) who had undergone LAAC performed using a WATCHMAN or LACbes® device from June 2016 to February 2022 were included. The primary efficacy endpoint included ischemic stroke, cardiovascular/unexplained death and device-related thrombus, while the primary safety endpoint included major peri-procedural complications and major bleeding events during clinical follow-ups. 1:1 propensity score matching (PSM) was performed.

RESULTS

After PSM, 184 patients were included in each group. The mean CHA2DS2-VASc score was 3.1 ± 1.5 (LACbes®) vs. 3.1 ± 1.4 (WATCHMAN), and the HAS-BLED score was 2.7 ± 1.1 vs. 2.7 ± 1.0. At a mean follow-up of 2.5 ± 1.5 vs. 2.4 ± 0.9 years, the defined three endpoints were comparable between the two groups. The occurrence of all-cause stroke was lower in 5/452 (1.8%) with LACbes® vs. 16/433 (3.7%) with WATCHMAN occluders (HR, 0.40, 95% confidence interval (CI), 0.18-0.89, P = 0.023), and the incidence of any bleeding was higher in the WATCHMAN group (41/433, 9.5% vs. 8/452, 1.8%; HR, 0.19, 95% CI, 0.11-0.33).

CONCLUSION

The LACbes® occluder exhibited comparable safety and efficacy of stroke prevention for AF when compared with the WATCHMAN device.

Для цитирования: Zhang Song, Xiong Sihuai, Zhang Sha, Chen Keyu, Wang Hua, Li Ke, Xu Xudong, Zhao Xianxian, Zhu Ni, Huang Xinmiao, Qin Yongwen, Guo Zhifu, Bai Yuan. WATCHMAN versus LACbes® device for percutaneous left atrial appendage closure: a single-center, propensity-matched study.. BMC cardiovascular disorders. 2025. DOI: 10.1186/s12872-024-04383-z.