MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2024.12.002

Медицинская библиотека · Academic radiology · 2024

The Feasibility of Measuring Central Blood Pressure with Bedside Echocardiography: An Observational Cross-Sectional Study.

Hussein Mohammed Salah, Amer Maged Z, Kabil Mohammed K, Saad Khaled, Elmonier Rady, Yousry Ahmed

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

Central arterial blood pressure (CBP) is considered a more valuable prognostic marker of major cardiovascular diseases than peripheral blood pressure. Non-invasive evaluation of central aortic pressure by Doppler echocardiography is a hopeful tool, avoiding many complications of invasive catheter strategy and diminishing time and costs.

METHODS

A total of 118 patients were referred for elective cardiac catheterization at the Cardiovascular Medicine Department, Mansoura University. Standard transthoracic echocardiography was simultaneously performed during invasive measurement of the central aortic pressure in the cardiac catheterization lab.

RESULTS

A significant correlation existed between invasive systolic, diastolic, and mean aortic pressure and aortic deceleration time, with P-values of 0.0003, 0.0002, and 0.0002, respectively. A significant correlation was also found between invasive systolic, diastolic, and mean aortic pressure and aortic Velocity Time Integral (VTI), with P-values of 0.006, 0.0004, and 0.0004, respectively. A significant and more reliable equation existed to calculate mean or diastolic central blood pressure by transthoracic aortic deceleration time values.

CONCLUSION

Central aortic pressure can be measured non-invasively using Doppler echocardiographic parameters: Left ventricular Mass (LVM), aortic deceleration time, and velocity time integral during routine echocardiography examination using rational equations. This represents a promising technique for further research.

Для цитирования: Hussein Mohammed Salah, Amer Maged Z, Kabil Mohammed K, Saad Khaled, Elmonier Rady, Yousry Ahmed. The Feasibility of Measuring Central Blood Pressure with Bedside Echocardiography: An Observational Cross-Sectional Study.. Academic radiology. 2024. DOI: 10.1016/j.acra.2024.12.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.