MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2024.08.035

Медицинская библиотека · JACC. Cardiovascular interventions · 2024

Transcatheter Edge-to-Edge Repair in Patients With Complex Tricuspid Valve Anatomy.

Adams David H, Tang Gilbert H L, Whisenant Brian K, Kodali Susheel K, Singh Gagan D, Fam Neil P, Kar Saibal, Price Matthew J, Spies Christian, Schwartz Jonathan G, Makkar Raj R, Tadros Peter, Asgar Anita W, Jorde Ulrich P, Benza Raymond L, Thourani Vinod H, McCarthy Patrick M, Bae Richard, Smith Thomas W R, Lim D Scott, Makar Moody M, Naik Hursh, Latib M Azeem, Sitges Marta, von Bardeleben Ralph Stephan, Lurz Philipp, Hamid Nadira, Hahn Rebecca T, Sorajja Paul

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Untreated severe tricuspid regurgitation (TR) carries a poor prognosis.

OBJECTIVES

The authors report the 1-year outcomes of transcatheter edge-to-edge repair (TEER) with the TriClip system (Abbott Structural Heart) in patients with complex tricuspid valve anatomies.

METHODS

The multicenter, international TRILUMINATE Pivotal (Trial to Evaluate Cardiovascular Outcomes in Patients Treated with the Tricuspid Valve Repair System Pivotal) trial included a single-arm cohort, with complex tricuspid valve anatomies excluded from the randomized arm (ie, anticipated TR reduction but not to moderate or less after TEER). The primary outcome endpoint of the single arm was 1-year survival with a Kansas City Cardiomyopathy Questionnaire score improvement ≥10 points.

RESULTS

In the primary analysis population (N = 100), the mean age was 80 ± 6 years, and 35% had a cardiac implantable electronic device lead. Nearly 90% of patients had massive or torrential TR, 44% had prior left-sided valve interventions, 63% had ≥4-segmental tricuspid leaflet morphology, and the coaptation gap averaged 7.4 ± 2.7 mm. The primary endpoint was met (outcome: 46.2%, performance goal: 30%; P = 0.0008). A total of 81% of subjects had moderate or less TR at 1 year. No major adverse events or deaths occurred within 30 days postprocedure. One-year all-cause mortality and heart failure hospitalization were 15% and 24%, respectively. Significant improvements in NYHA functional class and Kansas City Cardiomyopathy Questionnaire overall scores occurred and were maintained at 1 year.

CONCLUSIONS

In patients with complex tricuspid anatomies, TEER with the TriClip system demonstrated excellent procedural safety with significant TR reduction and associated improvements in quality of life at 1 year.

Для цитирования: Adams David H, Tang Gilbert H L, Whisenant Brian K, Kodali Susheel K, Singh Gagan D, Fam Neil P, Kar Saibal, Price Matthew J, Spies Christian, Schwartz Jonathan G, Makkar Raj R, Tadros Peter, Asgar Anita W, Jorde Ulrich P, Benza Raymond L, Thourani Vinod H, McCarthy Patrick M, Bae Richard, Smith Thomas W R, Lim D Scott, Makar Moody M, Naik Hursh, Latib M Azeem, Sitges Marta, von Bardeleben Ralph Stephan, Lurz Philipp, Hamid Nadira, Hahn Rebecca T, Sorajja Paul. Transcatheter Edge-to-Edge Repair in Patients With Complex Tricuspid Valve Anatomy.. JACC. Cardiovascular interventions. 2024. DOI: 10.1016/j.jcin.2024.08.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.