DOI 10.1038/s41551-024-01279-3

Медицинская библиотека · Nature biomedical engineering · 2024

Clinical validation of a wearable ultrasound sensor of blood pressure.

Zhou Sai, Park Geonho, Longardner Katherine, Lin Muyang, Qi Baiyan, Yang Xinyi, Gao Xiaoxiang, Huang Hao, Chen Xiangjun, Bian Yizhou, Hu Hongjie, Wu Ray S, Yue Wentong, Li Mohan, Lu Chengchangfeng, Wang Ruotao, Qin Siyu, Tasali Esra, Karrison Theodore, Thomas Isac, Smarr Benjamin, Kistler Erik B, Khiami Belal Al, Litvan Irene, Xu Sheng

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Options for the continuous and non-invasive monitoring of blood pressure are limited. Cuff-based sphygmomanometers are widely available, yet provide only discrete measurements. The clinical gold-standard approach for the continuous monitoring of blood pressure requires an arterial line, which is too invasive for routine use. Wearable ultrasound for the continuous and non-invasive monitoring of blood pressure promises to elevate the quality of patient care, yet the isolated sonographic windows in the most advanced prototypes can lead to inaccurate or error-prone measurements, and the safety and performance of these devices have not been thoroughly evaluated. Here we describe validation studies, conducted during daily activities at home, in the outpatient clinic, in the cardiac catheterization laboratory and in the intensive care unit, of the safety and performance of a wearable ultrasound sensor for blood pressure monitoring. The sensor has closely connected sonographic windows and a backing layer that improves the sensor's accuracy and reliability to meet the highest requirements of clinical standards. The validation results support the clinical use of the sensor.

Для цитирования: Zhou Sai, Park Geonho, Longardner Katherine, Lin Muyang, Qi Baiyan, Yang Xinyi, Gao Xiaoxiang, Huang Hao, Chen Xiangjun, Bian Yizhou, Hu Hongjie, Wu Ray S, Yue Wentong, Li Mohan, Lu Chengchangfeng, Wang Ruotao, Qin Siyu, Tasali Esra, Karrison Theodore, Thomas Isac, Smarr Benjamin, Kistler Erik B, Khiami Belal Al, Litvan Irene, Xu Sheng. Clinical validation of a wearable ultrasound sensor of blood pressure.. Nature biomedical engineering. 2024. DOI: 10.1038/s41551-024-01279-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.