MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.xjon.2024.06.018

Медицинская библиотека · JTCVS open · 2024

Investigation of a chronic single-stage sheep Fontan model.

Kelly John M, Hu Zinan, Takaesu Felipe, Watanabe Tatsuya, Storrs Judd, Blais Benjamin, Yuhara Satoshi, Morrison Adrienne, Nelson Kirsten, Ulziibayar Anudari, Heuer Eric, Anderson Cole, Jimenez Michael, Leland Joseph, Malbrue Raphael, Arsuaga-Zorrilla Carmen, Goodchild Laurie, Naguib Aymen, McKee Christopher, Varner Jordan, DeShetler Cameron, Spiess Joshua, Harrison Andrew, Boe Brian, Armstrong Aimee K, Salavitabar Arash, Hor Kan, Krishnamurthy Rajesh, Yates Andrew R, Shinoka Toshiharu, Carrillo Sergio A, Davis Michael E, Marsden Alison L, Breuer Christopher K

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Our goal was to conduct a hemodynamic analysis of a novel animal model of Fontan physiology. Poor late-term outcomes in Fontan patients are believed to arise from Fontan-induced hemodynamics, but the mechanisms remain poorly understood. Recent advances in surgical experimentation have resulted in the development of a chronic sheep model of Fontan physiology; however, detailed analysis of this model is lacking.

METHODS

We created a single-stage Fontan model in juvenile sheep with normal biventricular circulation. The superior vena cava was anastomosed to the main pulmonary artery, and the inferior vena cava was connected to the main pulmonary artery using an expanded polytetrafluoroethylene conduit. Longitudinal hemodynamics, including catheterization and magnetic resonance imaging were evaluated.

RESULTS

Four out of 12 animals survived, with the longest surviving animal living 3 years after single-stage Fontan. We showed a significant era effect regarding survival (1 out of 8 and subsequently 3 out of 4 animals surviving beyond 2 months) attributed in large part to the procedural learning curve. Key characteristics of Fontan hemodynamics, namely systemic venous hypertension and low normal cardiac output, were observed. However, recapitulation of passive human Fontan hemodynamics is affected by volume loading of the right ventricle given an anatomic difference in sheep azygous venous anatomy draining to the coronary sinus.

CONCLUSIONS

A significant learning curve exists to ensure long-term survival and future surgical modifications, including banding of the main pulmonary artery and ligation of the azygous to coronary sinus connection are promising strategies to improve the fidelity of model hemodynamics.

Для цитирования: Kelly John M, Hu Zinan, Takaesu Felipe, Watanabe Tatsuya, Storrs Judd, Blais Benjamin, Yuhara Satoshi, Morrison Adrienne, Nelson Kirsten, Ulziibayar Anudari, Heuer Eric, Anderson Cole, Jimenez Michael, Leland Joseph, Malbrue Raphael, Arsuaga-Zorrilla Carmen, Goodchild Laurie, Naguib Aymen, McKee Christopher, Varner Jordan, DeShetler Cameron, Spiess Joshua, Harrison Andrew, Boe Brian, Armstrong Aimee K, Salavitabar Arash, Hor Kan, Krishnamurthy Rajesh, Yates Andrew R, Shinoka Toshiharu, Carrillo Sergio A, Davis Michael E, Marsden Alison L, Breuer Christopher K. Investigation of a chronic single-stage sheep Fontan model.. JTCVS open. 2024. DOI: 10.1016/j.xjon.2024.06.018.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.