MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.124.014224

Медицинская библиотека · Circulation. Cardiovascular interventions · 2024

Transcatheter Mitral Valve Replacement Using Annular Reduction by Cinching With TEER in the Commissure (ARCTIC).

Condos Gregory J, Elison David, Vincent Logan L, Harari Rafael, Sanina Cristina, Jelacic Srdjan, Sheu Richard, Chung Christine J, Aldea Gabriel S, Mackensen G Burkhard, McCabe James M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Mitral annular calcification with valve dysfunction remains a challenging syndrome. Operative risk is high, and available transcatheter therapies are limited.

METHODS

This study describes our initial experience with a novel procedure to address large mitral annuli when no surgical or trial-based transcatheter mitral valve replacement device is available. The rationale was to shorten the intercommissural distance using commissural mitral transcatheter edge-to-edge repair (TEER) followed by valve-in-mitral annular calcification transcatheter mitral valve replacement with a balloon-expandable aortic valve platform. Patients with long intercommissural distances and large mitral annulus areas were selected based on a high perceived risk of transcatheter valve embolization. Patients underwent mitral TEER with MitraClip in a commissural position, followed immediately by transseptal transcatheter mitral valve replacement with a 29 mm SAPIEN 3 valve.

RESULTS

Thirteen patients were included. Median intercommissural distance and annular area were 39.1 mm and 930 mm2, respectively. Commissural mitral TEER was successful in all patients with no instances of single leaflet detachment. In 10 of 13 instances, an NTW device size was used. In 12 of 13 patients, valve implantation was successful, including 1 case that required a second valve for atrial positioning of the first valve. In 1 case, frank valve embolization into the left atrium occurred. Among the 12 successful cases, paravalvular leak was 1+ or less, and there were no instances of paravalvular leak adjacent to the TEER device.

CONCLUSIONS

In patients with large annuli and sufficient annular calcium, a hybrid mitral TEER and valve replacement with the SAPIEN platform can be successfully used to facilitate transcatheter mitral valve replacement.

Для цитирования: Condos Gregory J, Elison David, Vincent Logan L, Harari Rafael, Sanina Cristina, Jelacic Srdjan, Sheu Richard, Chung Christine J, Aldea Gabriel S, Mackensen G Burkhard, McCabe James M. Transcatheter Mitral Valve Replacement Using Annular Reduction by Cinching With TEER in the Commissure (ARCTIC).. Circulation. Cardiovascular interventions. 2024. DOI: 10.1161/circinterventions.124.014224.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.