MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2024.132614

Медицинская библиотека · International journal of cardiology · 2024

Left atrial appendage closure guided by fusion of 3D computational modelling on real-time fluoroscopy: A multicenter experience.

Garot Philippe, Gall Emmanuel, Zendjebil Sandra, Cepas-Guillén Pedro, Iriart Xavier, Farah Bruno, Skurk Carsten, Gautier Alexandre, Ho Cheuk Bong, Bavo Alessandra M, Vaillant Régis, Horvilleur Jérôme, Freixa Xavier, Saw Jacqueline, de Backer Ole

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Patient-specific 3-dimensional (3D) computational modelling offers a tailored approach with promising results, but experience using digital-twin fusion on real-time fluoroscopy to guide left atrial appendage closure (LAAC) is unreported.

OBJECTIVES

To assess whether LAAC guided by fusion of a 3D computational model on real-time fluoroscopy is safe and effective.

METHODS

We included retrospectively through a multicenter registry all consecutive patients with non-valvular atrial fibrillation (AF) who underwent LAAC guided by artificial intelligence (AI)-enabled computer simulations (FEops, Gent, Belgium) fusion with real-time fluoroscopy. Operators selected the appropriate device size and position in relation to the LAA using FEops HEARTguide™, and a digital twin was provided for image fusion. The primary efficacy endpoint was successful LAAC with the use of a single device, without moderate or greater peri-device leak and/or device related thrombus (DRT) on follow-up imaging. The primary safety endpoint was a composite of major procedural complications including tamponade, stroke, systemic embolism, major bleeding, and device embolization.

RESULTS

A total of 106 patients underwent LAAC with an Amulet™ or Watchman FLX™ device using CT-model-fluoroscopy fusion imaging. Device implantation was successful in 100 % of cases. The primary efficacy endpoint was met in 82 patients (89 %). A single-device SINGLE-deployment LAAC procedure was observed in 49 cases (46 %). The primary safety endpoint occurred in 2 patients (1.9 %). After a median follow-up of 405 days, two patients suffered an ischemic stroke and four expired.

CONCLUSIONS

Fusion of a CT-based 3D computational model on real-time fluoroscopy is a safe and effective approach that may optimize transcatheter LAAC outcomes.

Для цитирования: Garot Philippe, Gall Emmanuel, Zendjebil Sandra, Cepas-Guillén Pedro, Iriart Xavier, Farah Bruno, Skurk Carsten, Gautier Alexandre, Ho Cheuk Bong, Bavo Alessandra M, Vaillant Régis, Horvilleur Jérôme, Freixa Xavier, Saw Jacqueline, de Backer Ole. Left atrial appendage closure guided by fusion of 3D computational modelling on real-time fluoroscopy: A multicenter experience.. International journal of cardiology. 2024. DOI: 10.1016/j.ijcard.2024.132614.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.