MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euae256

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024

Transcatheter non-acute retrieval of the tine-based leadless ventricular pacemaker.

Funasako Moritoshi, Hála Pavel, Janotka Marek, Šorf Jan, Machová Lucie, Petrů Jan, Chovanec Milan, Škoda Jan, Šedivá Lucie, Šimon Jaroslav, Dujka Libor, Reddy Vivek Y, Neužil Petr

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: We report our single-centre experience of mid-term to long-term retrieval and reimplantation of a tine-based leadless pacemaker [Micra transcatheter pacing system (TPS)]. The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favourable in specific scenarios.

METHODS AND

RESULTS

We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7 mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. After an implantation duration of 3.1 ± 2.8 years (range 0.4-9.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 ± 16 min, and the fluoroscopy time was 18.0 ± 6.6 min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications.

CONCLUSION

A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.

Для цитирования: Funasako Moritoshi, Hála Pavel, Janotka Marek, Šorf Jan, Machová Lucie, Petrů Jan, Chovanec Milan, Škoda Jan, Šedivá Lucie, Šimon Jaroslav, Dujka Libor, Reddy Vivek Y, Neužil Petr. Transcatheter non-acute retrieval of the tine-based leadless ventricular pacemaker.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2024. DOI: 10.1093/europace/euae256.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.