Impact of Renal and Liver Function on Clinical Outcomes Following Tricuspid Valve Transcatheter Edge-to-Edge Repair.

Jorde Ulrich P, Benza Raymond, McCarthy Patrick M, Ailawadi Gorav, Whisenant Brian, Makkar Raj, Tadros Peter, Naik Hursh, Fam Neil, Sauer Andrew J, Murthy Sandhya, Kar Saibal, von Bardeleben Ralph Stephan, Hahn Rebecca T, Hamid Nadira, Zbinden Jacob, Sorajja Paul, Adams David

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The TRILUMINATE Pivotal trial is a prospective, randomized, controlled study of patients with severe tricuspid regurgitation (TR). Venous congestion due to TR may lead to end-organ dysfunction and failure. The potential to reverse or stop further deterioration in end-organ function is an important goal of treatment.

OBJECTIVES

This study sought to examine changes in end-organ function after tricuspid transcatheter edge-to-edge repair (TEER) and assess the association of baseline end-organ function with heart failure (HF) hospitalizations and mortality.

METHODS

Subjects were randomized 1:1 to either the TEER group (TriClip System + medical therapy) or control group (medical therapy alone). Laboratory assessments and TR grading were performed at baseline and at all follow-up visits (discharge, 30 days, 6 months, and 12 months). An independent echocardiography core laboratory assessed TR severity and an independent clinical events committee adjudicated adverse events.

RESULTS

A total of 572 subjects were enrolled and randomized (285 TEER, 287 control patients). Patients with moderate-to-severe end-organ impairment (estimated glomerular ejection fraction [eGFR] <45 mL/min/1.73 m2 or Model for End-Stage Liver Disease excluding INR [MELD-XI] >15) at baseline had increased incidence of HF hospitalization and death through 12 months, regardless of treatment. There were no statistically significant differences between TEER and control patients in eGFR or MELD-XI at 12 months. In subgroup analyses examining only successful TEER patients (moderate or less TR at discharge) compared with control patients, as well as when censoring patients with normal baseline values, both eGFR (+3.55 ± 1.04 mL/min/1.73 m2 vs 0.07 ± 1.10 mL/min/1.73 m2; P = 0.022) and MELD-XI (-0.52 ± 0.18 vs 0.34 ± 0.18; P = 0.0007) improved.

CONCLUSIONS

Baseline end-organ function was associated with HF hospitalization and death in patients with severe TR. At 12 months, eGFR and MELD-XI scores were not statistically significantly different between the overall TEER and control groups. In patients who had successful TEER, statistically significant, yet small, favorable changes occurred for both eGFR and MELD-XI. Further investigation is needed to assess whether these changes in end-organ function after successful TEER are clinically meaningful and reduce HF hospitalization or death. (Clinical Trial to Evaluate Cardiovascular Outcomes In Patients Treated With the Tricuspid Valve Repair System Pivotal [TRILUMINATE Pivotal]; NCT03904147).

Для цитирования: Jorde Ulrich P, Benza Raymond, McCarthy Patrick M, Ailawadi Gorav, Whisenant Brian, Makkar Raj, Tadros Peter, Naik Hursh, Fam Neil, Sauer Andrew J, Murthy Sandhya, Kar Saibal, von Bardeleben Ralph Stephan, Hahn Rebecca T, Hamid Nadira, Zbinden Jacob, Sorajja Paul, Adams David. Impact of Renal and Liver Function on Clinical Outcomes Following Tricuspid Valve Transcatheter Edge-to-Edge Repair.. Journal of the American College of Cardiology. 2024. DOI: 10.1016/j.jacc.2024.08.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.