Transjugular Transcatheter Tricuspid Valve Replacement: Early Compassionate Use Outcomes.

Stolz Lukas, Cheung Anson, Boone Robert, Fam Neil, Ong Geraldine, Villablanca Pedro, Jabri Ahmad, De Backer Ole, Mølller Jacob Eifer, Tchétché Didier, Oliva Omar, Chak-Yu So Kent, Lam Yat-Yin, Latib Azeem, Scotti Andrea, Coisne Augustin, Sudre Arnaud, Dreyfus Julien, Nejjari Mohammed, Favre Paul-Emile, Cruz-Gonzalez Ignacio, Estévez-Loureiro Rodrigo, Barreiro-Perez Manuel, Makkar Raj, Patel Dhairya, Leurent Guillaume, Donal Erwan, Modine Thomas, Hausleiter Jörg

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Data on procedural and early outcomes after transjugular transcatheter tricuspid valve replacement (TTVR) are limited.

OBJECTIVES

This study sought to evaluate first-in-man procedural and clinical outcomes after transjugular TTVR with a special focus on patients who received large device sizes in whom TTVR outcomes have been questioned.

METHODS

The retrospective registry included patients who underwent TTVR using the LuX-Valve Plus system (Jenscare Biotechnology Co Ltd) for symptomatic tricuspid regurgitation (TR) from January 2022 until February 2024 at 15 international centers in a compassionate use setting. The endpoints were procedural TR reduction, in-hospital death, adverse events, and 1-month survival. We further stratified results according to the size of the implanted device (<55 vs ≥55 mm).

RESULTS

The registry included a total of 76 patients at a median age of 78 years (Q1-Q3: 72-83 years, 47.4% women). TR was reduced to ≤2+ and ≤1+ in 94.7% and 90.8% of patients (75.0% of patients received TTVR devices ≥55 mm) with well-sustained results at 1-month follow-up (TR ≤2+ in 95.0% and ≤1+ 86.8%). Residual TR was paravalvular in all cases. In-hospital death occurred in 4 patients (5.3%). Four patients (5.3%) underwent cardiac surgery during index hospitalization. Major in-hospital bleeding events occurred in 5 patients (6.6%). New in-hospital pacemaker implantation was required in 3.9% of patients in the overall cohort (5.7% in "pacemaker-naive" individuals). No cases of valve thrombosis, stroke, myocardial infarction, or pulmonary embolism were observed. At 1-month follow-up, survival was 94.4%, and NYHA functional class significantly improved. One further patient received a pacemaker, 1 further bleeding event occurred, and 2 patients underwent reintervention or surgery within the first 30 days after TTVR. No differences in procedural outcomes or adverse events were observed after stratification for valve size.

CONCLUSIONS

Transjugular TTVR appears to be a safe and effective treatment option for patients with severe TR with comparable outcomes in very large tricuspid anatomies.

Для цитирования: Stolz Lukas, Cheung Anson, Boone Robert, Fam Neil, Ong Geraldine, Villablanca Pedro, Jabri Ahmad, De Backer Ole, Mølller Jacob Eifer, Tchétché Didier, Oliva Omar, Chak-Yu So Kent, Lam Yat-Yin, Latib Azeem, Scotti Andrea, Coisne Augustin, Sudre Arnaud, Dreyfus Julien, Nejjari Mohammed, Favre Paul-Emile, Cruz-Gonzalez Ignacio, Estévez-Loureiro Rodrigo, Barreiro-Perez Manuel, Makkar Raj, Patel Dhairya, Leurent Guillaume, Donal Erwan, Modine Thomas, Hausleiter Jörg. Transjugular Transcatheter Tricuspid Valve Replacement: Early Compassionate Use Outcomes.. JACC. Cardiovascular interventions. 2024. DOI: 10.1016/j.jcin.2024.06.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.