MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjimp/qyad014

Медицинская библиотека · European heart journal. Imaging methods and practice · 2023

Non-invasive estimation of mean pulmonary artery pressure by cardiovascular magnetic resonance in under 2 min scan time.

Abdula Goran, Ramos Joao G, Marlevi David, Fyrdahl Alexander, Engblom Henrik, Sörensson Peder, Giese Daniel, Jin Ning, Sigfridsson Andreas, Ugander Martin

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Non-invasive estimation of mean pulmonary artery pressure (mPAP) by cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow analysis has shown excellent agreement with invasive right heart catheterization. However, clinical application is limited by relatively long scan times. Therefore, the aim of this study was to evaluate the accuracy and time reduction of compressed sensing (CS) accelerated acquisition for mPAP estimation.

METHODS AND

RESULTS

Patients (n = 51) referred for clinical CMR at 1.5 T or 3 T underwent imaging with both a prototype CS-accelerated and a non-CS-accelerated flow sequence acquiring time-resolved multiple 2D slice phase-contrast three-directional velocity-encoded images covering the pulmonary artery. Prototype software was used for the blinded analysis of pulmonary artery (PA) vortex duration to estimate mPAP as previously validated. CS-accelerated and non-CS-accelerated acquisition showed increased mPAP in 22/51 (43%) and 24/51 (47%) patients, respectively. The mean bias for estimating mPAP between the two methods was 0.1 ± 1.9 mmHg and the intraclass correlation coefficient was 0.97 (95% confidence interval 0.94-0.98). Effective scan time was lower for the CS-accelerated acquisition (1 min 55 s ± 27 s vs. 9 min 6 s ± 2 min 20 s, P < 0.001, 79% reduction).

CONCLUSIONS

CS-accelerated CMR acquisition enables preserved accuracy for estimating mPAP compared to a non-CS-accelerated sequence, allowing for an average scan time of less than 2 min. CS-acceleration thereby increases the clinical utility of CMR 4D flow analysis to estimate mPAP.

Для цитирования: Abdula Goran, Ramos Joao G, Marlevi David, Fyrdahl Alexander, Engblom Henrik, Sörensson Peder, Giese Daniel, Jin Ning, Sigfridsson Andreas, Ugander Martin. Non-invasive estimation of mean pulmonary artery pressure by cardiovascular magnetic resonance in under 2 min scan time.. European heart journal. Imaging methods and practice. 2023. DOI: 10.1093/ehjimp/qyad014.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.